Conf Proc IEEE Eng Med Biol Soc. 2011;2011:4580-3. doi: 10.1109/IEMBS.2011.6091134.

Performance optimization of ERP-based BCIs using dynamic stopping.

Author information

  • 1BBCI group of the Machine Learning Department, Berlin Institute of Technology, Berlin, Germany.


Brain-computer interfaces based on event-related potentials face a trade-off between the speed and accuracy of the system, as both depend on the number of iterations. Increasing the number of iterations leads to a higher accuracy but reduces the speed of the system. This trade-off is generally dealt with by finding a fixed number of iterations that give a good result on the calibration data. We show here that this method is sub optimal and increases the performance significantly in only one out of five datasets. Several alternative methods have been described in literature, and we test the generalization of four of them. One method, called rank diff, significantly increased the performance over all datasets. These findings are important, as they show that 1) one should be cautious when reporting the potential performance of a BCI based on post-hoc offline performance curves and 2) simple methods are available that do boost performance.

[PubMed - indexed for MEDLINE]