Format

Send to

Choose Destination
See comment in PubMed Commons below
Pharmacoepidemiol Drug Saf. 2012 Jun;21(6):622-30. doi: 10.1002/pds.2247. Epub 2011 Oct 12.

Are all quantitative postmarketing signal detection methods equal? Performance characteristics of logistic regression and Multi-item Gamma Poisson Shrinker.

Author information

  • 1Novartis Pharma AG, Basel, Switzerland. conny.berlin@novartis.com

Abstract

PURPOSE:

The detection of safety signals with medicines is an essential activity to protect public health. Despite widespread acceptance, it is unclear whether recently applied statistical algorithms provide enhanced performance characteristics when compared with traditional systems. Novartis has adopted a novel system for automated signal detection on the basis of disproportionality methods within a safety data mining application (Empirica™ Signal System [ESS]). ESS uses two algorithms for routine analyses: empirical Bayes Multi-item Gamma Poisson Shrinker and logistic regression (LR).

METHODS:

A model was developed comprising 14 medicines, categorized as "new" or "established." A standard was prepared on the basis of safety findings selected from traditional sources. ESS results were compared with the standard to calculate the positive predictive value (PPV), specificity, and sensitivity. PPVs of the lower one-sided 5% and 0.05% confidence limits of the Bayes geometric mean (EB05) and of the LR odds ratio (LR0005) almost coincided for all the drug-event combinations studied.

RESULTS:

There was no obvious difference comparing the PPV of the leading Medical Dictionary for Regulatory Activities (MedDRA) terms to the PPV for all terms. The PPV of narrow MedDRA query searches was higher than that for broad searches. The widely used threshold value of EB05 = 2.0 or LR0005 = 2.0 together with more than three spontaneous reports of the drug-event combination produced balanced results for PPV, sensitivity, and specificity.

CONCLUSIONS:

Consequently, performance characteristics were best for leading terms with narrow MedDRA query searches irrespective of applying Multi-item Gamma Poisson Shrinker or LR at a threshold value of 2.0. This research formed the basis for the configuration of ESS for signal detection at Novartis.

Copyright © 2011 John Wiley & Sons, Ltd.

[PubMed - indexed for MEDLINE]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Wiley
    Loading ...
    Write to the Help Desk