    J Magn Reson Imaging. 2011 Aug;34(2):468-73. doi: 10.1002/jmri.22623.

    MR properties of brown and white adipose tissues.

    Source

    Department of Radiology, University of California, San Diego, San Diego, California, USA.

    Abstract

    PURPOSE:

    To explore the MR signatures of brown adipose tissue (BAT) compared with white adipose tissue (WAT) using single-voxel MR spectroscopy.

    MATERIALS AND METHODS:

    (1) H MR STEAM spectra were acquired from a 3 Tesla clinical whole body scanner from seven excised murine adipose tissue samples of BAT (n=4) and WAT (n=3). Spectra were acquired at multiple echo times (TEs) and inversion times (TIs) to measure the T1, T2, and T2-corrected peak areas. A theoretical triglyceride model characterized the fat in terms of number of double bonds (ndb) and number of methylene-interrupted double bonds (nmidb).

    RESULTS:

    Negligible differences between WAT and BAT were seen in the T1 and T2 of fat and the T2 of water. However, the water fraction in BAT was higher (48.5%) compared with WAT (7.1%) and the T1 of water was lower in BAT (618 ms) compared with WAT (1053 ms). The fat spectrum also differed, indicating lower levels of unsaturated triglycerides in BAT (ndb=2.7, nmidb=0.7) compared with WAT (ndb=3.3, nmidb=1.0).

    CONCLUSION:

    We have demonstrated that there are several key MR-based signatures of BAT and WAT that may allow differentiation on MR imaging.

    Copyright © 2011 Wiley-Liss, Inc.

    PMID:
    21780237
    [PubMed - indexed for MEDLINE]
    PMCID:
    PMC3146031
    Free PMC Article

    Images from this publication.See all images (4)Free text

    Figure 1
    Figure 2
    Figure 3
    Figure 4

      Supplemental Content

      Icon for John Wiley & Sons, Inc. Icon for PubMed Central

      Save items

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk