Display Settings:

Format

Send to:

Choose Destination
    Int J Gynaecol Obstet. 2011 May;113(2):112-5. Epub 2011 Mar 30.

    Experience with TachoSil in obstetric and gynecologic surgery.

    Source

    Department of Obstetrics and Gynecology, Hôpital Tenon, Assistance Publique des Hôpitaux de Paris, CancerEst, Université Pierre et Marie Curie (UPMC), Paris, France.

    Abstract

    OBJECTIVE:

    To evaluate the feasibility and effectiveness of using TachoSil during obstetric and gynecologic surgery.

    METHODS:

    The retrospective cohort study, conducted at a French university hospital, included women who experienced perioperative bleeding requiring the use of TachoSil during 2007-2009. The following information was collected: patient age, indication for the use of TachoSil, need for a blood transfusion, type of surgery performed, postoperative course, and traceability of TachoSil.

    RESULTS:

    TachoSil was used in 84 women. The main indications for the surgical interventions requiring TachoSil were ovarian malignancy (n=18), fibroma (n=17), breast cancer (n=11), and endometrial cancer (n=10). In 16 women, TachoSil was applied to the uterine serosa, particularly after cesarean delivery or polymyomectomy; in 7 women, it was applied to the major vascular axis. Red cell packs were infused in 24 women during surgery (average 3 packs per woman). Three women required repeat surgery. The use of TachoSil was not recorded in the operative reports of 43 (51%) women.

    CONCLUSION:

    The present findings confirm that the use of TachoSil in gynecologic and obstetric surgeries is effective and well tolerated. Measures to improve the traceability of TachoSil use are recommended.

    Copyright © 2011 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

    PMID:
    21453918
    [PubMed - indexed for MEDLINE]