    Ann Biomed Eng. 2011 Jun;39(6):1668-79. doi: 10.1007/s10439-011-0278-5. Epub 2011 Feb 25.

    Mass-spring model for simulation of heart valve tissue mechanical behavior.

    Source

    Department of Cardiac Surgery, Children's Hospital, Boston, MA, USA. peter.hammer@childrens.harvard.edu

    Abstract

    Heart valves are functionally complex, making surgical repair difficult. Simulation-based surgical planning could facilitate repair, but current finite element (FE) studies are prohibitively slow for rapid, clinically oriented simulations. Mass-spring (M-S) models are fast but can be inaccurate. We quantify speed and accuracy differences between an anisotropic, nonlinear M-S and an efficient FE membrane model for simulating both biaxial and pressure loading of aortic valve (AV) leaflets. The FE model incurs approximately 10 times the computational cost of the M-S model. For simulated biaxial loading, mean error in normal strains is <1% for both FE and M-S models for equibiaxial loading but increases for non-equibiaxial states for the M-S model (7%). The M-S model was less able to simulate shear behavior, with mean strain error of approximately 80%. For pressurized AV leaflets, the M-S model predicts similar leaflet dimensions to the FE model (within 2.6%), and the coaptation zone is similar between models. The M-S model simulates in-plane behavior of AV leaflets considerably faster than the FE model and with only minor differences in the deformed mesh. While the M-S model does not allow explicit control of shear response, shear does not strongly influence shape of the simulated AV under pressure.

    PMID:
    21350891
    [PubMed - indexed for MEDLINE]
    PMCID:
    PMC3097299
    Free PMC Article

    Images from this publication.See all images (8)Free text

    FIGURE 1
    FIGURE 3
    FIGURE 5
    FIGURE 7
    FIGURE 2
    FIGURE 4
    FIGURE 6
    FIGURE 8

      Supplemental Content

      Icon for Springer Icon for PubMed Central

      Save items

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk