    Integr Biol (Camb). 2010 Nov;2(11-12):630-8. doi: 10.1039/c0ib00030b. Epub 2010 Oct 18.

    An arrayed high-content chemotaxis assay for patient diagnosis.

    Source

    Department of Biomedical Engineering, Wisconsin Institutes for Medical Research, University of Wisconsin, 1111 Highland Av, Madison 53705, Wisconsin, USA.

    Abstract

    Chemotaxis assays are essential tools for the study of gradient sensing and directed cell migration, and have the potential to aid in the diagnosis and characterization of patients with immune disorders. Current methods are limited in their ability to meet the more demanding requirements for clinical applications. Because patient samples have a short lifespan and sometimes a limited volume (e.g. pediatrics), the operational requirements for an efficient chemotaxis assay are increased in the clinical setting. Here we describe a microscale assay platform for gradient generation that overcomes these limitations. Passive fluidic methods are leveraged to provide a reliable microfluidic gradient generation device, operable in only three pipetting steps. In addition, arrayed imaging and advanced cell tracking algorithms enabled a 50-fold increase in throughput over current methods. These methods were employed to aid in the diagnostic evaluation of an infant who presented with severe, recurrent bacterial infections. Analysis of the infant's neutrophils revealed impaired cell polarization and chemotaxis in a gradient of the chemoattractant fMLP. The patient was subsequently diagnosed with an inhibitory mutation in the Rho GTPase, Rac2. The approach also enabled a microenvironmental screen of human primary neutrophil chemotaxis on fibronectin, fibrinogen and laminin with results suggesting that fibronectin, although commonly used, may not be the most appropriate matrix protein for chemotaxis assays. Together, these findings demonstrate the use of arrayed micro-devices to aid in the diagnosis of a primary immunodeficiency disorder, and illustrate the capability for increased throughput microenvironmental studies and screening targeted to specific human diseases.

    PMID:
    20953490
    [PubMed - indexed for MEDLINE]

      Supplemental Content

      Icon for Royal Society of Chemistry

      Save items

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk