    Heart Rhythm. 2011 Feb;8(2):256-62. Epub 2010 Oct 8.

    Value of the signal-averaged electrocardiogram in arrhythmogenic right ventricular cardiomyopathy/dysplasia.

    Source

    Al-Sabah Arrhythmia Institute, St. Luke's and Roosevelt Hospitals, and Columbia University College of Physicians & Surgeons, New York, New York 10025, USA.

    Abstract

    BACKGROUND:

    Arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) is an inherited disease that causes structural and functional abnormalities of the right ventricle (RV). The presence of late potentials as assessed by the signal-averaged electrocardiogram (SAECG) is a minor task force criterion.

    OBJECTIVE:

    The purpose of this study was to examine the diagnostic and clinical value of the SAECG in a large population of genotyped ARVC/D probands.

    METHODS:

    We compared the SAECGs of 87 ARVC/D probands (age 37 ± 13 years, 47 males) diagnosed as affected or borderline by task force criteria without using the SAECG criterion with 103 control subjects. The association of SAECG abnormalities was also correlated with clinical presentation, surface ECG, ventricular tachycardia (VT) inducibility at electrophysiologic testing, implantable cardioverter-defibrillator therapy for VT, and RV abnormalities as assessed by cardiac magnetic resonance imaging (cMRI).

    RESULTS:

    Compared with controls, all three components of the SAECG were highly associated with the diagnosis of ARVC/D (P <.001). They include the filtered QRS duration (97.8 ± 8.7 ms vs 119.6 ± 23.8 ms), low-amplitude signal (24.4 ± 9.2 ms vs 46.2 ± 23.7 ms), and root mean square amplitude of the last 40 ms of the QRS (50.4 ± 26.9 μV vs 27.9 ± 36.3 μV). The sensitivity of using SAECG for diagnosis of ARVC/D was increased from 47% using the established 2 of 3 criteria (i.e., late potentials) to 69% by using a modified criterion of any 1 of 3 criteria, while maintaining a high specificity of 95%. Abnormal SAECG as defined by this modified criterion was associated with a dilated RV volume and decreased RV ejection fraction detected by cMRI (P <.05). SAECG abnormalities did not vary with clinical presentation or reliably predict spontaneous or inducible VT and had limited correlation with ECG findings.

    CONCLUSION:

    Using 1 of 3 SAECG criteria contributed to increased sensitivity and specificity for the diagnosis of ARVC/D. This finding is incorporated in the recent modification of the task force criteria.

    Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

    PMID:
    20933608
    [PubMed - indexed for MEDLINE]
    PMCID:
    PMC3077127
    Free PMC Article

    Images from this publication.See all images (2) Free text

    Figure 2
    Figure 1

      Supplemental Content

      Icon for Elsevier Science Icon for PubMed Central

      Save items

      loading

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk