Detection of methicillin-resistant Staphylococcus aureus (MRSA) in specimens from various body sites: performance characteristics of the BD GeneOhm MRSA assay, the Xpert MRSA assay, and broth-enriched culture in an area with a low prevalence of MRSA infections

J Clin Microbiol. 2010 Nov;48(11):3882-7. doi: 10.1128/JCM.00670-10. Epub 2010 Sep 22.

Abstract

Universal surveillance upon patient admission is important in reducing the transmission of methicillin-resistant Staphylococcus aureus (MRSA) and associated disease in hospitals. High costs for the health care system in conjunction with MRSA have promoted the development of rapid screening methods to detect MRSA carriers. This study compared two real-time PCR methods, the BD GeneOhm MRSA assay (BDGO) and the Xpert MRSA assay, with broth-enriched culture to define their performance characteristics and rapidity in an area with low MRSA prevalence. In total, 414 swabs from the nose and 389 swabs from the groin from 425 patients were tested. Of those 425 patients, 378 had swabs from both the nose and groin in parallel. Two hundred thirty-one and 194 patients were randomly assigned to the BDGO group and the Xpert MRSA group, respectively. In general, sensitivity, specificity, and negative predictive value (NPV) were high for the BDGO (100%, 98.5%, and 100%, respectively) and the Xpert MRSA (100%, 98.2%, and 100%, respectively), irrespective of whether or not nasal and inguinal specimens were considered alone or combined. In contrast, the positive predictive value (PPV) was lower: before the resolution of discrepant results, the PPVs for nasal and inguinal specimens alone and combined were 87.5%, 86.7%, and 82.4% for the BDGO and 91.7%, 66.7%, and 92.9% for the Xpert MRSA, respectively. After the resolution of discrepant results, PPVs were 93.8%, 93.3% and 94.1% for the BDGO and 91.7%, 88.9% and 92.9% for the Xpert MRSA, respectively. With the BDGO, 4 of 16 carriers were each identified by nasal or inguinal swabs alone, whereas in the Xpert MRSA group, 4 of 13 carriers were exclusively identified by nasal swabs and 2 of 13 were identified by inguinal swabs alone. Both PCR methods showed no significant difference in the number of discrepant results (odds ratio, 0.70 [P = 0.789]), but specimens from wounds and other body sites (axilla, vagina, and throat) produced discrepancies more often than nasal and groin specimens (odds ratios, 4.724 [P = 0.058] and 12.163 [P < 0.001], respectively). The facts that no false-negative PCR results were detected and increased PPVs were found after the resolution of discrepant results point to PCR as the actual gold standard. Since both sensitivity and NPV were exceptionally high for PCR, backup cultures may, therefore, be unnecessary in an area with low prevalence and with a preemptive isolation strategy but may still be useful for PCR-positive specimens because of the lower PPV for both methods and the possibility of susceptibility testing. The median time for analysis, including extraction, hands-on time, and actual PCR was 2 h 20 min for the Xpert MRSA versus 5 h 40 min for the BDGO. Concerning reporting time, including administration and specimen collection, the Xpert MRSA was faster than the BDGO (7 h 50 min versus 17 h).

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Bacteriological Techniques / methods*
  • Groin / microbiology
  • Humans
  • Methicillin-Resistant Staphylococcus aureus / isolation & purification*
  • Nose / microbiology
  • Polymerase Chain Reaction / methods*
  • Predictive Value of Tests
  • Prevalence
  • Reagent Kits, Diagnostic
  • Sensitivity and Specificity
  • Staphylococcal Infections / diagnosis*
  • Staphylococcal Infections / epidemiology
  • Staphylococcal Infections / microbiology*

Substances

  • Reagent Kits, Diagnostic