Format

Send to:

Choose Destination
See comment in PubMed Commons below
Virol J. 2010 Sep 22;7:252. doi: 10.1186/1743-422X-7-252.

Measurement of Epstein-Barr virus DNA load using a novel quantification standard containing two EBV DNA targets and SYBR Green I dye.

Author information

  • 1Virology Department, Centre For Infectious Diseases & Microbiology Laboratory Services, Institute of Clinical Pathology & Medical Research, Institute Road, Westmead Hospital, Westmead 2145, New South Wales, Australia. mlay4697@uni.sydney.edu.au

Abstract

BACKGROUND:

Reactivation of Epstein-Barr virus (EBV) infection may cause serious, life-threatening complications in immunocompromised individuals. EBV DNA is often detected in EBV-associated disease states, with viral load believed to be a reflection of virus activity. Two separate real-time quantitative polymerase chain reaction (QPCR) assays using SYBR Green I dye and a single quantification standard containing two EBV genes, Epstein-Barr nuclear antigen-1 (EBNA-1) and BamHI fragment H rightward open reading frame-1 (BHRF-1), were developed to detect and measure absolute EBV DNA load in patients with various EBV-associated diseases. EBV DNA loads and viral capsid antigen (VCA) IgG antibody titres were also quantified on a population sample.

RESULTS:

EBV DNA was measurable in ethylenediaminetetraacetic acid (EDTA) whole blood, peripheral blood mononuclear cells (PBMCs), plasma and cerebrospinal fluid (CSF) samples. EBV DNA loads were detectable from 8.0 × 10(2) to 1.3 × 10(8) copies/ml in post-transplant lymphoproliferative disease (n = 5), 1.5 × 10(3) to 2.0 × 10(5) copies/ml in infectious mononucleosis (n = 7), 7.5 × 10(4) to 1.1 × 10(5) copies/ml in EBV-associated haemophagocytic syndrome (n = 1), 2.0 × 10(2) to 5.6 × 10(3) copies/ml in HIV-infected patients (n = 12), and 2.0 × 10(2) to 9.1 × 10(4) copies/ml in the population sample (n = 218). EBNA-1 and BHRF-1 DNA were detected in 11.0% and 21.6% of the population sample respectively. There was a modest correlation between VCA IgG antibody titre and BHRF-1 DNA load (rho = 0.13, p = 0.05) but not EBNA-1 DNA load (rho = 0.11, p = 0.11).

CONCLUSION:

Two sensitive and specific real-time PCR assays using SYBR Green I dye and a single quantification standard containing two EBV DNA targets, were developed for the detection and measurement of EBV DNA load in a variety of clinical samples. These assays have application in the investigation of EBV-related illnesses in immunocompromised individuals.

PMID:
20860842
[PubMed - indexed for MEDLINE]
PMCID:
PMC2958162
Free PMC Article
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for BioMed Central Icon for PubMed Central
    Loading ...
    Write to the Help Desk