Prevalence and predictors of off-label use of cardiac resynchronization therapy in patients enrolled in the National Cardiovascular Data Registry Implantable Cardiac-Defibrillator Registry.

Author information

  • 1Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.

Abstract

OBJECTIVES:

The purpose of the study was to define the extent and nature of cardiac resynchronization therapy (CRT) device usage outside consensus guidelines using national data.

BACKGROUND:

Recent literature has shown that the application of CRT in clinical practice frequently does not adhere to evidence-based consensus guidelines. Factors underlying these practices have not been fully explored.

METHODS:

From the National Cardiovascular Data Registry's Implantable Cardiac-Defibrillator Registry, we defined a cohort of 45,392 cardiac resynchronization therapy-defibrillator (CRT-D) implants between January 2006 and June 2008 with a primary prevention indication. We defined "off-label" implants as those in which the ejection fraction was >35%, the New York Heart Association functional class was below III, or the QRS interval duration was <120 ms in the absence of a documented need for ventricular pacing. The relationships between patient, implanting physician, and hospital characteristics with off-label use were explored with multivariable hierarchical logistic regression models.

RESULTS:

Overall, 23.7% of devices were placed without meeting all 3 implant criteria, most often due to New York Heart Association functional class below III (13.1% of implants) or QRS interval duration <120 ms (12.0%). Atrial fibrillation/flutter, previous percutaneous coronary intervention, and the performance of an electrophysiology study before implant were independently associated with increased odds of off-label use, whereas diabetes mellitus, increasing age, and female sex were associated with decreased odds. Physician training and insurance payer were weakly associated with the likelihood of off-label use.

CONCLUSIONS:

Nearly 1 in 4 patients receiving CRT devices in the study time frame did not meet guideline-based indications. Given the evolving evidence base supporting the use of CRT, these practices require careful scrutiny.

Copyright (c) 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

PMID:
20797489
[PubMed - indexed for MEDLINE]
PMCID:
PMC2958057
Free PMC Article

Images from this publication.See all images (2)Free text

Figure 1
Figure 2
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Elsevier Science Icon for PubMed Central
    Loading ...
    Write to the Help Desk