    Microsc Res Tech. 2010 Aug 23. [Epub ahead of print]

    Fluorescence correlation spectroscopy, raster image correlation spectroscopy, and number and brightness on a commercial confocal laser scanning microscope with analog detectors (Nikon C1).

    Source

    Centre for Bioactive Discovery in Health and Ageing, School of Science and Technology, University of New England, Armidale, Australia.

    Abstract

    Fluorescence correlation spectroscopy (FCS) was developed in 1972 by Magde, Elson and Webb. Photon counting detectors and avalanche photodiodes have become standards in FCS to the point that there is a widespread belief that these detectors are essential to perform FCS experiments, despite the fact that FCS was developed using analog detectors. Spatial and temporal intensity fluctuation correlations using analog detection on a commercial Olympus Fluoview 300 microscope have been reported by Brown et al. (2008). However, each analog instrument has its own idiosyncrasies that need to be understood before using the instrument for FCS. In this work, we explore the capabilities of the Nikon C1, a low-cost confocal microscope, to obtain single point FCS, Raster-scan image correlation spectroscopy (RICS), and Number and Brightness data both in solution and incorporated into the membrane of giant unilamellar vesicles. We show that it is possible to obtain dynamic information about fluorescent molecules from single point FCS, RICS, and Number and Brightness using the Nikon C1. We highlighted the fact that care should be taken in selecting the acquisition parameters to avoid possible artifacts due to the detector noise. However, due to relatively large errors in determining the distribution of digital levels for a given microscope setting, the system is probably only adequate for determining relative brightness within the same image. Microsc. Res. Tech., 2010. (c) 2010 Wiley-Liss, Inc.

    PMID:
    20734406
    [PubMed - as supplied by publisher]
    PMCID:
    PMC3001136
    Free PMC Article

    Images from this publication.See all images (13) Free text

    Figure 2
    Figure 4
    Figure 6
    Figure 8
    Figure 10
    Figure 12
    Figure 1
    Figure 3
    Figure 5
    Figure 7
    Figure 9
    Figure 11
    Figure 13

      Supplemental Content

      Icon for John Wiley & Sons, Inc. Icon for PubMed Central

      Save items

      loading

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk