Display Settings:

Format

Send to:

Choose Destination
Contemp Clin Trials. 2010 Nov;31(6):514-23. doi: 10.1016/j.cct.2010.08.004. Epub 2010 Aug 17.

Accelerometer use in a physical activity intervention trial.

Author information

  • 1Temple University, Center for Obesity Research and Education, 3223 N Broad St Suite 175, Philadelphia, PA 19140, United States. napolita@temple.edu

Abstract

This paper describes the application of best practice recommendations for using accelerometers in a physical activity (PA) intervention trial, and the concordance of different methods for measuring PA. A subsample (n = 63; 26%) of the 239 healthy, sedentary adults participating in a PA trial (mean age = 47.5; 82% women) wore the ActiGraph monitor at all 3 assessment time points. ActiGraph data were compared with self-report (i.e., PA weekly recall and monthly log) and fitness variables. Correlations between the PA recall and ActiGraph for moderate intensity activity ranged from 0.16-0.48 and from 0.28-0.42 for vigorous intensity activity. ActiGraph and fitness [estimated VO(2)(ml/kg/min)] had correlations of 0.15-0.45. The ActiGraph and weekly self-report were significantly correlated at all time points (correlations ranged from 0.23 to 0.44). In terms of detecting intervention effects, intervention groups recorded more minutes of at least moderate-intensity PA on the ActiGraph than the control group at 6 months (min = 46.47, 95% CI = 14.36-78.58), but not at 12 months. Limitations of the study include a small sample size and only 3 days of ActiGraph monitoring. To obtain optimal results with accelerometers in clinical trials, the authors recommend following best practice recommendations: detailed protocols for monitor use, calibration of monitors and validation of data quality, and use of validated equations for analysis. The ActiGraph has modest concordance with other assessment tools and is sensitive to change over time. However, until more information validating the use of accelerometry in clinical trials becomes available, properly administered self-report measures of PA should remain part of the assessment battery.

Copyright © 2010 Elsevier Inc. All rights reserved.

PMID:
20723619
[PubMed - indexed for MEDLINE]
PMCID:
PMC2956863
Free PMC Article

Images from this publication.See all images (2)Free text

Figure 1
Figure 2
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Elsevier Science Icon for PubMed Central
    Loading ...
    Write to the Help Desk