Display Settings:

Format

Send to:

Choose Destination
We are sorry, but NCBI web applications do not support your browser and may not function properly. More information
    J Hand Surg Am. 2010 Aug;35(8):1246-50. doi: 10.1016/j.jhsa.2010.05.011.

    Optimal fixation of acute scaphoid fractures: finite element analysis.

    Source

    Department of Orthopedic Surgery, Hadassah-Hebrew University Medical Center, Jerusalem, Israel. shail@hadassah.org.il

    Abstract

    PURPOSE:

    The hypothesis of this study was that more stable fixation of acute scaphoid fractures may be achieved by a screw placed perpendicular to the fracture plane than along the long axis of the scaphoid, as previously suggested. We examined this assumption on different fracture patterns using a finite element analysis model.

    METHODS:

    A computed tomography scan of an intact scaphoid of a young man provided the data set for all fracture models. We used semiautomatic segmentation to create 3-dimensional computer models of the 3 simple fracture configurations: oblique, transverse waist, and proximal fractures, according to the Herbert classification. Each fracture type was analyzed, using finite elements, for its biomechanical response to 2 types of virtual fixation: a screw placed either perpendicular to the fracture plane or centrally along the long axis of the scaphoid. We measured motion at the fracture plane (in millimeters) and strain in the screw threads (in millipascals).

    RESULTS:

    Considerably less motion was measured at the fracture plane with the perpendicular screw compared with the long axis screw, especially in the oblique-type fractures: (1) Herbert-type B1 oblique fracture mean motion of 0.05 mm (+/-0.03) for the perpendicular screw versus 0.28 mm (+/-0.05) for the long axis screw; (2) B2 transverse waist fracture mean motion of 0.06 mm (+/-0.03) for the perpendicular screw versus 0.18 mm (+/-0.06) for the long axis screw; and (3) B3 proximal fracture mean motion of 0.07 mm (+/-0.01) for the perpendicular screw versus 0.28 mm (+/-0.011) for the long axis screw. Higher strains were measured on the screw placed perpendicular to the fracture.

    CONCLUSIONS:

    According to this model, higher fixation stability is achieved when the scaphoid is fixated perpendicular to the fracture. In transverse waist fractures, a centrally placed screw will also be perpendicular to the fracture, which explains the results of previous models.

    Copyright 2010. Published by Elsevier Inc.

    PMID:
    20684923
    [PubMed - indexed for MEDLINE]

      Supplemental Content

      Icon for Elsevier Science

      Save items

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk