    J Asthma. 2010 Sep;47(7):762-7. doi: 10.3109/02770903.2010.485664.

    Clinically useful spirometry in preschool-aged children: evaluation of the 2007 American Thoracic Society Guidelines.

    Source

    Division of Respiratory Diseases, Children’s Hospital Boston, 300 Longwood Avenue, Boston, MA 02115, U.S.A.

    Abstract

    RATIONALE:

    In 2007 the American Thoracic Society (ATS) recommended guidelines for acceptability and repeatability for assessing spirometry in preschool children. The authors aim to determine the feasibility of spirometry among children in this age group performing spirometry for the first time in a busy clinical practice.

    METHODS:

    First-time spirometry for children age 4 to 5 years old was selected from the Children's Hospital Boston Pulmonary Function Test (PFT) database. Maneuvers were deemed acceptable if ( 1 ) the flow-volume loop showed rapid rise and smooth descent; ( 2 ) the back extrapolated volume (V(be)), the volume leaked by a subject prior to the forced maneuver, was ≤ 80 ml and 12.5% of forced vital capacity (FVC); and ( 3 ) cessation of expiratory flow was at a point ≤ 10% of peak expiratory flow rate (PEFR). Repeatability was determined by another acceptable maneuver with forced expiratory volume in t seconds (FEV(t)) and FVC within 10% or 0.1 L of the best acceptable maneuver. Post hoc analysis compared spirometry values for those with asthma and cystic fibrosis to normative values.

    RESULTS:

    Two hundred and forty-eight preschool children performed spirometry for the first time between August 26, 2006, and August 25, 2008. At least one technically acceptable maneuver was found in 82.3% (n = 204) of the tests performed. Overall, 54% of children were able to perform acceptable and repeatable spirometry based on the ATS criteria. Children with asthma or cystic fibrosis did not have spirometry values that differed significantly from healthy controls. However, up to 29% of the overall cohort displayed at least one abnormal spirometry value.

    CONCLUSIONS:

    Many preschool-aged children are able to perform technically acceptable and repeatable spirometry under normal conditions in a busy clinical setting. Spirometry may be a useful screen for abnormal lung function in this age group.

    PMID:
    20653495
    [PubMed - indexed for MEDLINE]
    PMCID:
    PMC2943961
    Free PMC Article

    Images from this publication.See all images (1)Free text

    Figure 1

      Supplemental Content

      Icon for PubMed Central

      Save items

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk