Display Settings:

Format

Send to:

Choose Destination
See comment in PubMed Commons below
Resuscitation. 2010 Aug;81(8):1014-8. doi: 10.1016/j.resuscitation.2010.03.041. Epub 2010 Jun 1.

Effect of cardiopulmonary resuscitation on intubation using a Macintosh laryngoscope, the AirWay Scope, and the gum elastic bougie: A manikin study.

Author information

  • 1Department of Anesthesiology, International Medical Center, Saitama Medical University, 1397-1 Yamane, Hidaka, Saitama 350-1241, Japan. kmaruyam@saitama-med.ac.jp

Abstract

BACKGROUND:

Physicians could encounter difficult intubation during cardiopulmonary resuscitation (CPR) in trauma patients due to the patient's movement from continuous chest compression and to cervical stabilisation. Therefore, first, we evaluated the impact of chest compression with or without cervical stabilisation on intubation with a Macintosh laryngoscope. Next, we compared difficulty in intubation among the Macintosh laryngoscope, AirWay Scope (AWS), and gum elastic bougie (GEB) with the Macintosh laryngoscope in three simulated CPR scenarios in a randomised, controlled, cross-over study design.

METHODS:

Twenty-three anaesthetists intubated the trachea of a manikin (ALS Skill Master, Laerdal Medical Japan, Tokyo, Japan) using the Macintosh laryngoscope, AWS, and GEB in the control scenario, chest compression scenario, and chest compression with cervical stabilisation scenario. Difficulty in intubation was rated on a 5-point scale and the intubation time was measured.

RESULTS:

Continuous chest compression increased difficulty in intubation with the Macintosh laryngoscope, compared with the control scenario. Concurrent application of cervical stabilisation further increased the difficulty, compared with application of chest compression alone. Of the three devices compared, the AWS facilitated the easiest intubation, and the GEB facilitated the second-easiest intubation in all scenarios, though the intubation time was slightly longer with the GEB than with other devices.

CONCLUSION:

CPR employing continuous chest compression with or without cervical stabilisation caused difficult intubation with the Macintosh laryngoscope. The AWS and GEB facilitated the easiest and second-easiest intubation, respectively, even during CPR employing continuous chest compression with or without cervical stabilisation in a manikin.

Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

Comment in

PMID:
20605669
[PubMed - indexed for MEDLINE]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Icon for Elsevier Science
    Loading ...
    Write to the Help Desk