Display Settings:

Format

Send to:

Choose Destination
Opt Express. 2010 Jun 21;18(13):14262-9. doi: 10.1364/OE.18.014262.

Temporal-imaging system with simple external-clock triggering.

Author information

  • 1School of Applied and Engineering Physics, Cornell University, Ithaca, NY 14853, USA. dhb29@cornell.edu

Abstract

We demonstrate a temporal imaging system based on parametric mixing that allows simple triggering from an external clock by using a time-lens-based pump laser. We integrate our temporal imaging system into a time-to-frequency measurement scheme and demonstrate the ability to perform characterization of temporal waveforms with 1.4-ps resolution and a 530-ps record length. We also integrate our system into a temporal-magnification scheme and demonstrate single-shot operation with a 113 x magnification factor, 1.5-ps resolution, and 220-ps record length.

PMID:
20588561
[PubMed - indexed for MEDLINE]