Injury. 2012 Apr;43(4):505-8. doi: 10.1016/j.injury.2010.04.011. Epub 2010 May 13.

Oblique axis body fracture--pitfalls in management.

Author information

  • 1Department of Neurosurgery, The Alfred Hospital, Victoria 3181, Australia. tony.goldschlager@med.monash.edu.au

Abstract

BACKGROUND:

Transverse fractures through the body of the axis, rather than at the base of the odontoid are uncommon and management with an external orthosis is usually recommended. Oblique fractures through the body of the axis accompanying a hangman's fracture have not been reported and are not described as part of any classification system. Such fractures may be at high risk for treatment failure in an external orthosis.

CASE DESCRIPTION:

We report on a case of an oblique axis fracture that failed treatment with external orthosis. Posterior instrumented fusion was employed successfully using a C1-C3 and C4 poly axial screw rod construct. Frameless stereotaxy and a biomodel were useful surgical adjuncts. Twelve month follow up revealed bony union in an asymptomatic patient.

CONCLUSIONS:

Oblique fractures of the body of the axis can displace in a halo-thoracic orthosis. Serial radiological review is required to detect displacement prior to fracture union. Oblique fractures of the body of the axis can be managed surgically with preservation of atlanto-occipital motion, resulting in satisfactory clinical and radiological outcomes.

Copyright © 2010 Elsevier Ltd. All rights reserved.