Display Settings:

Format

Send to:

Choose Destination
    Yonsei Med J. 2010 May;51(3):345-53.

    Non-invasive estimation of systolic blood pressure and diastolic blood pressure using photoplethysmograph components.

    Source

    Department of Biomedical Engineering, Yonsei University, 234 Meaji, Heungeup, Wonju 220-710, Korea.

    Abstract

    PURPOSE:

    Photoplethysmography (PPG) is a noninvasive optical technology that detects changes in blood volume in the vascular system. This study aimed to investigate the possibilities of monitoring the cardiovascular system status by using PPG.

    MATERIALS AND METHODS:

    Forced hemodynamic changes were induced using cardiac stimulants; dopamine and epinephrine, and PPG components were recorded by a noninvasive method at the peripheral blood vessels. The results were compared among 6 dogs. Endotracheal intubation was performed after an intramuscular injection of 25 mg/kg ketamine sulfate, and anesthesia was maintained with 2% enflurane. After stabilizing the animals for 15 min, 16 mg/mL diluted dopamine was injected into a vein for 2 min at 20 microg/kg min(-1) by using an infusion pump. Thereafter, the infusion pump was stopped, and 1 mg epinephrine was injected intravenously. Fluid administration was controlled to minimize preload change in blood pressure.

    RESULTS:

    After stimulant administration, systolic blood pressure (SBP) and diastolic blood pressures (DBP) increased. The direct current (DC) component, which reflects changes in blood volume, decreased while the alternating current (AC) component, which reflects changes in vascular compliance and resistance, increased. The correlation coefficient between SBP and the foot of the DC component was 0.939 (p < 0.01), while it was 0.942 (p < 0.01) for DBP and the peak of the DC component. The AC component could predict the increase in vascular resistance from a stable pulse blood volume, even with increased pulse pressure.

    CONCLUSION:

    These results support the possibility that PPG components may be used for easy and noninvasive measurement of hemodynamic changes in the cardiovascular system.

    PMID:
    20376886
    [PubMed - indexed for MEDLINE]
    PMCID:
    PMC2852789
    Free PMC Article

    Images from this publication.See all images (5) Free text

    Fig. 1
    Fig. 3
    Fig. 5
    Fig. 2
    Fig. 4

      Supplemental Content

      Icon for PubMed Central

      Save items

      loading

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk