    J Clin Microbiol. 2010 May;48(5):1661-6. doi: 10.1128/JCM.00003-10. Epub 2010 Mar 24.

    Multicenter evaluation of the LightCycler methicillin-resistant Staphylococcus aureus (MRSA) advanced test as a rapid method for detection of MRSA in nasal surveillance swabs.

    Source

    NorthShore University HealthSystem, Department of Pathology and Laboratory Medicine, 2650 Ridge Avenue, Walgreen Bldg., SB525, Evanston, IL 60201, USA. lance1@uchicago.edu

    Abstract

    The rate of methicillin-resistant Staphylococcus aureus (MRSA) infection continues to rise in many health care settings. Rapid detection of MRSA colonization followed by appropriate isolation can reduce transmission and infection. We compared the performance of the new Roche LightCycler MRSA advanced test to that of the BD GeneOhm MRSA test and culture. Double-headed swabs were used to collect anterior nasal specimens from each subject. For both tests, DNA was extracted and real-time PCR was performed according to manufacturer's instructions. For culture, one swab of the pair was plated directly to CHROMagar MRSA. The swab paired with the BD GeneOhm MRSA test was also placed into an enrichment broth and then plated to CHROMagar MRSA. Colonies resembling staphylococci were confirmed as S. aureus by standard methods. Discrepant specimens had further testing with additional attempts to grow MRSA as well as sample amplicon sequencing. Agreement between results for the two swabs was 99.3% for those with valid results. A total of 1,402 specimens were tested using direct culture detection of MRSA as the gold standard; 187 were culture positive for MRSA. The LightCycler MRSA advanced test had relative sensitivity and specificity of 95.2% (95% confidence interval [CI]: 91.1% to 97.8%) and 96.4% (95% CI: 95.2% to 97.4%), respectively. The BD GeneOhm assay had relative sensitivity and specificity of 95.7% (95% CI: 91.7% to 98.1%) and 91.7% (95% CI: 90.0% to 93.2%), respectively. Following discrepancy analysis, the relative sensitivities of the LightCycler MRSA advanced test and the BD GeneOhm MRSA assay were 92.2 and 93.2%, respectively; relative specificities were 98.9 and 94.2%, respectively. Specificity was significantly better (P<0.001) with the LightCycler MRSA advanced test. The sensitivity of direct culture was 80.4%. The LightCycler MRSA advanced test is a useful tool for sensitive and rapid detection of MRSA nasal colonization.

    PMID:
    20335423
    [PubMed - indexed for MEDLINE]
    PMCID:
    PMC2863939
    Free PMC Article

      Supplemental Content

      Icon for HighWire Icon for PubMed Central

      Save items

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk