Radiology. 2010 May;255(2):517-26. doi: 10.1148/radiol.09091134. Epub 2010 Mar 23.

Renal inflammation: targeted iron oxide nanoparticles for molecular MR imaging in mice.

Author information

  • 1Department of Anesthesiology, University of Colorado-Denver School of Medicine, 1775 N Aurora Ct, M20-3103, Aurora, CO 80045, USA.

Abstract

PURPOSE:

To determine the feasibility of T2-weighted magnetic resonance (MR) imaging in the noninvasive quantification of renal inflammation by using superparamagnetic iron oxide (SPIO) nanoparticles targeted to tissue-bound C3 activation fragments in a mouse model of lupus nephritis.

MATERIALS AND METHODS:

All animal procedures were approved by the University of Colorado-Denver animal care and use committee. SPIO nanoparticles were encapsulated by using amine-functionalized phospholipids. A recombinant protein containing the C3d-binding region of complement receptor type 2 (CR2) was then conjugated to the surface of the SPIO nanoparticle. Five MRL/lpr mice (a model of lupus nephritis) and six C57BL/6 wild-type mice were assessed with T2-weighted MR imaging at baseline and after SPIO injection. The same five MRL/lpr mice and three C57BL/6 mice also underwent MR imaging after injection of CR2-targeted SPIO. A series of T2-weighted pulses with 16 echo times was used to enable precise T2 mapping and calculation of T2 relaxation times in the cortex and outer and inner medulla of the kidneys, as well as in the spleen, muscle, and fat. The effects of treatment and animal genotype on T2 relaxation times were analyzed with repeated-measures analysis of variance.

RESULTS:

At baseline, the T2-weighted signal intensity in the kidneys of MRL/lpr mice was higher than that in the kidneys of wild-type mice. Injection of untargeted SPIO did not alter the T2-weighted signal in the kidneys in either strain of mice. Injection of CR2-targeted SPIO in MRL/lpr mice, however, caused a significant accumulation of targeted iron oxide with a subsequent decrease in T2 relaxation times in the cortex and outer and inner medulla of the kidneys. No changes in T2 relaxation time were observed in the wild-type mice after injection of targeted SPIO.

CONCLUSION:

Injection of CR2-conjugated SPIO caused a significant reduction in T2-weighted MR imaging signal and T2 relaxation time in nephritic kidneys.

Comment in

PMID:
20332377
[PubMed - indexed for MEDLINE]
PMCID:
PMC2858816
Free PMC Article

Images from this publication.See all images (20)Free text

Figure 1a:
Figure 1b:
Figure 1c:
Figure 1d:
Figure 2a:
Figure 2b:
Figure 2c:
Figure 2d:
Figure 2e:
Figure 2f:
Figure 3a:
Figure 3b:
Figure 3c:
Figure 3d:
Figure 4a:
Figure 4b:
Figure 4c:
Figure 5a:
Figure 5b:
Figure 6a:
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Atypon Icon for PubMed Central
    Loading ...
    Write to the Help Desk