Eur J Epidemiol. 2010 Jun;25(6):385-92. doi: 10.1007/s10654-010-9442-8. Epub 2010 Mar 23.

Effect of inter-reader variability on outcomes in studies using carotid intima media thickness quantified by carotid ultrasonography.

Author information

  • 1Collaborative Health Studies Coordinating Center, Department of Biostatistics, University of Washington, Bldg.29, Suite 310, 6200 NE 74th Street, Seattle, WA 98115, USA. jacd@uw.edu

Abstract

Systematic differences between readers or equipment in imaging studies are not uncommon; failure to account for such differences when using Carotid Ultrasonography may introduce bias into associations between carotid intima media thickness (cIMT) and outcomes. We demonstrate the impact of this source of systematic measurement error (SME) using data on 5,521 participants from the Multi-Ethnic Study of Atherosclerosis (MESA) and 661 participants from the Study of Fat Redistribution and Metabolic Change in HIV Infection (FRAM). Participants were between 37 and 78 years old. Two outcomes were considered: (1) the effect of HIV infection on cIMT (between study) and (2) the association of cIMT with cardiovascular events (within study). All estimates were adjusted for demographics (age, gender, and ethnicity) and for traditional cardiovascular disease risk factors (smoking, blood pressure, diabetes and cholesterol). When comparing the FRAM and MESA cohorts to estimate the association of HIV infection on common cIMT, accounting for machine and reader variability (between study variability) reduced the difference associated with HIV infection from +0.080 mm (95% Confidence Interval (CI):0.065-0.095) to +0.037 mm (95% CI:0.003 to 0.072) while internal cIMT declined from +0.254 mm (95% CI:0.205-0.303) to +0.192 mm (95% CI:0.076-0.308). Attenuation of the association between cIMT and cardiovascular endpoints occurred when within study reader variability was not accounted for. The effect of SME due to use of multiple readers or machines is most important when comparisons are made between two different study populations. Within-cohort measurement error dilutes the association with events.

PMID:
20309612
[PubMed - indexed for MEDLINE]
PMCID:
PMC3161119
Free PMC Article

Publication Types, MeSH Terms, Grant Support

Publication Types

MeSH Terms

Grant Support

PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Springer Icon for PubMed Central
    Loading ...
    Write to the Help Desk