International collaborative study to establish reference preparations to standardise haemagglutination testing for anti-A and anti-B in normal intravenous immunoglobulins by the direct method

Pharmeur Bio Sci Notes. 2010 Apr;2010(1):39-50.

Abstract

A joint project (coded BSP089) was run by the European Directorate for the Quality of Medicines & HealthCare (EDQM) of the Council of Europe, the National Institute for Biological Standards and Control (NIBSC) on behalf of the World Health Organization (WHO) and the Center for Biologics Evaluation and Research (CBER) of the U.S. Food and Drug Administration (FDA) to evaluate, in an international collaborative study, 3 lyophilised intravenous immunoglobulin (IVIG) preparations for their suitability to serve as Reference Preparations to standardise and control the highly variable haemagglutination testing for anti-A and anti-B in IVIG products. 23 laboratories tested candidate IVIG reference preparations consisting of a Positive control, a Negative control and a specifically formulated Limit test reference preparation to define the maximum (e.g., pharmacopoeial) limits of anti-A and anti-B haemagglutinins in IVIG products, where limits are applicable. Laboratories performed direct haemagglutination using papain-treated erythrocytes and/or indirect anti-globulin tests. For both methods, there was up to 16-fold variation in anti-A and anti-B titres, although there was good agreement over a 2-fold titre range for anti-A and anti-B between laboratories using the direct method for both the Positive control and Limit reference preparations. Comparative titration data for the Positive control and Limit reference preparations indicated that the use of a 'Limit' test reference preparation would facilitate identification of higher titre batches when the direct haemagglutination method is used. The Positive control, Negative control and Limit test preparations were adopted in November 2008 by the Commission of the European Pharmacopoeia (Ph. Eur.) as Biological Reference Preparations. The same preparations have been established as reference reagents by the WHO and the U.S FDA, including the maximal specifications defined by the Limit test preparation. This will facilitate global standardisation of haemagglutination tests for anti-A and anti-B, ensure that such tests are sufficiently sensitive and specific, and facilitate identification of batches that exceed maximum recommended levels of anti-A and anti-B antibodies.

MeSH terms

  • ABO Blood-Group System / immunology*
  • Europe
  • Hemagglutination Tests / standards*
  • Immunoglobulins, Intravenous / immunology
  • Immunoglobulins, Intravenous / standards*
  • International Cooperation
  • Isoantibodies / analysis*
  • Laboratories / standards
  • Pharmacopoeias as Topic
  • Quality Control
  • Reference Standards
  • United States
  • United States Food and Drug Administration
  • World Health Organization

Substances

  • ABO Blood-Group System
  • Immunoglobulins, Intravenous
  • Isoantibodies