Display Settings:

Format

Send to:

Choose Destination
We are sorry, but NCBI web applications do not support your browser and may not function properly. More information
    Clin Vaccine Immunol. 2010 Apr;17(4):674-82. doi: 10.1128/CVI.00408-09. Epub 2010 Feb 3.

    Optimization and application of a multiplex bead-based assay to quantify serotype-specific IgG against Streptococcus pneumoniae polysaccharides: response to the booster vaccine after immunization with the pneumococcal 7-valent conjugate vaccine.

    Source

    Laboratory for Infectious Diseases and Perinatal Screening, National Institute for Public Health and the Environment, Antonie van Leeuwenhoeklaan 9, Bilthoven 3721 MA, Netherlands.

    Abstract

    We describe the optimization and application of a multiplex bead-based assay (Luminex) to quantify antibodies against polysaccharides of 13 pneumococcal serotypes. In the optimized multiplex immunoassay (MIA), intravenous immune globulin was introduced as an in-house reference serum, and nonspecific reacting antibodies were adsorbed with the commercial product pneumococcal C polysaccharides Multi. The antibody concentrations were assessed in 188 serum samples obtained pre- and post-booster vaccination at 11 months after administration of a primary series of the pneumococcal seven-valent conjugate vaccine (PCV-7) at 2, 3, and 4 months of age. The results of the MIA were compared with those of the ELISA for the serotypes included in the seven-valent conjugated polysaccharide vaccine and for a non-vaccine serotype, serotype 6A. The geometric mean concentrations of the antibodies determined by MIA were slightly higher than those determined by ELISA. The correlations between the assays were good, with R(2) values ranging from 0.84 to 0.91 for all serotypes except serotype 19F, for which R(2) was 0.70. The concentrations of antibody against serotype 6A increased after the administration of PCV-7 due to cross-reactivity with serotype 6B. The differences between the results obtained by ELISA and MIA suggest that the internationally established protective threshold of 0.35 microg/ml should be reevaluated for use in the MIA and may need to be amended separately for each serotype.

    PMID:
    20130129
    [PubMed - indexed for MEDLINE]
    PMCID:
    PMC2849341
    Free PMC Article

    Images from this publication.See all images (7)Free text

    FIG. 1.
    FIG. 2.
    FIG. 3.
    FIG. 4.
    FIG. 5.
    FIG. 6.
    FIG. 7.

      Supplemental Content

      Icon for HighWire Icon for PubMed Central

      Save items

      Recent activity

      • Optimization and application of a multiplex bead-based assay to quantify serotyp...
        Optimization and application of a multiplex bead-based assay to quantify serotype-specific IgG against Streptococcus pneumoniae polysaccharides: response to the booster vaccine after immunization with the pneumococcal 7-valent conjugate vaccine.
        Clin Vaccine Immunol. 2010 Apr ;17(4):674-82. doi: 10.1128/CVI.00408-09. Epub 2010 Feb 3 .
        PubMed

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk