Display Settings:

Format

Send to:

Choose Destination

    Should we use closed or open infusion containers for prevention of bloodstream infections?

    Source

    Medical College of Buenos Aires, Argentina.

    Abstract

    BACKGROUND:

    Hospitalized patients in critical care settings are at risk for bloodstream infections (BSI). Most BSIs originate from a central line (CL), and they increase length of stay, cost, and mortality. Open infusion containers may increase the risk of contamination and administration-related (CLAB) because they allow the entry of air into the system, thereby also providing an opportunity for microbial entry. Closed infusion containers were designed to overcome this flaw. However, open infusion containers are still widely used throughout the world.The objective of the study was to determine the effect of switching from open (glass, burettes, and semi-rigid) infusion containers to closed, fully collapsible, plastic infusion containers (Viaflex) on the rate and time to onset of central line-associated bloodstream infections CLABs.

    METHODS:

    An open label, prospective cohort, active healthcare-associated infection surveillance, sequential study was conducted in four ICUs in Mexico. Centers for Disease Control National Nosocomial Infections Surveillance Systems definitions were used to define device-associated infections.

    RESULTS:

    A total of 1,096 adult patients who had a central line in place for >24 hours were enrolled. The CLAB rate was significantly higher during the open versus the closed container period (16.1 versus 3.2 CLAB/1000 central line days; RR = 0.20, 95% CI = 0.11-0.36, P < 0.0001). The probability of developing CLAB remained relatively constant in the closed container period (1.4% Days 2-4 to 0.5% Days 8-10), but increased in the open container period (4.9% Days 2-4 to 5.4% Days 8-10). The chance of acquiring a CLAB was significantly decreased (81%) in the closed container period (Cox proportional hazard ratio 0.19, P < 0.0001). Mortality was statistically significantly lower during the closed versus the open container period (23.4% versus 16.1%; RR = 0.69, 95% CI = 0.54-0.88, P < 0.01).

    CONCLUSIONS:

    Closed infusion containers significantly reduced CLAB rate, the probability of acquiring CLAB, and mortality.

    PMID:
    20122280
    [PubMed - indexed for MEDLINE]
    PMCID:
    PMC2829484
    Free PMC Article

    Images from this publication.See all images (5) Free text

    Figure 1
    Figure 3
    Figure 5
    Figure 2
    Figure 4

      Supplemental Content

      Icon for BioMed Central Icon for PubMed Central

      Save items

      loading

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk