Display Settings:

Format

Send to:

Choose Destination
    Otol Neurotol. 2010 Apr;31(3):455-9.

    Clinical utility of electrocochleography in the diagnosis and management of Ménière's disease: AOS and ANS membership survey data.

    Source

    School of Medicine, Division of Otolaryngology-Head and Neck Surgery, Department of Surgery, University of California-San Diego, San Diego, CA 92103, U.S.A.

    Abstract

    OBJECTIVE:

    Evaluate the clinical use of electrocochleography (ECoG) for diagnosis/treatment of Ménière's disease among members of the American Otological Society (AOS) and American Neurotology Society (ANS).

    SUBJECTS:

    Clinically active members of the AOS/ANS.

    MAIN OUTCOME MEASURE:

    Survey responses.

    RESULTS:

    A total of 143 responses were received from 344 possible respondents (41.6%). In suspected cases of Ménière's disease, 45.5% of respondents did not use ECoG at all, 17.5 % used ECoG routinely, and 37.1% used it only in questionable cases. Electrocochleography users differed widely in electrode approach and stimulus modality used, with extratympanic approach and click stimuli used most frequently. Most respondents (73.2%) thought that ECoG is a test of indeterminate value. Only 3.6% required an abnormal ECoG to diagnose endolymphatic hydrops. An abnormal test was a requirement to proceed with ablative therapy for just 8.6% of respondents. Still, 77.9% think that ECoG findings do fluctuate with activity of the disorder, but only 18.0% agree that when the ECoG reverts to normal, one can predict remission of symptoms. Almost half of respondents (46.7%) reported that they have now stopped ordering ECoG due to variability in results and lack of correlation with their patients' symptoms.

    CONCLUSION:

    Among AOS/ANS members, there is low clinical use of ECoG in diagnosis/management of Ménière's disease. For approximately half of respondents, ECoG has no role in their clinical practice. Electrocochleography was used routinely by only 1 in 6 respondents. Those who used ECoG differed widely in electrode placement and type of stimuli paradigm used.

    PMID:
    20104195
    [PubMed - indexed for MEDLINE]
    PMCID:
    PMC3037765
    Free PMC Article

    Images from this publication.See all images (4) Free text

    Figure 1
    Figure 3
    Figure 2
    Figure 4

      Supplemental Content

      Icon for PubMed Central

      Save items

      loading

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk