Display Settings:

Format

Send to:

Choose Destination
    Harm Reduct J. 2009 Dec 22;6:37.

    Effect of filtration on morphine and particle content of injections prepared from slow-release oral morphine tablets.

    Source

    School of Pharmacy, University of Tasmania, Hobart, Tasmania, Australia. mclean@utas.edu.au

    Abstract

    BACKGROUND:

    Injections of mixtures prepared from crushed tablets contain insoluble particles which can cause embolisms and other complications. Although many particles can be removed by filtration, many injecting drug users do not filter due to availability, cost or performance of filters, and also due to concerns that some of the dose will be lost.

    METHODS:

    Injection solutions were prepared from slow-release morphine tablets (MS Contin) replicating methods used by injecting drug users. Contaminating particles were counted by microscopy and morphine content analysed by liquid chromatography before and after filtration.

    RESULTS:

    Unfiltered tablet extracts contained tens of millions of particles with a range in sizes from < 5 microm to > 400 microm. Cigarette filters removed most of the larger particles (> 50 microm) but the smaller particles remained. Commercial syringe filters (0.45 and 0.22 microm) produced a dramatic reduction in particles but tended to block unless used after a cigarette filter. Morphine was retained by all filters but could be recovered by following the filtration with one or two 1 ml washes. The combined use of a cigarette filter then 0.22 microm filter, with rinses, enabled recovery of 90% of the extracted morphine in a solution which was essentially free of tablet-derived particles.

    CONCLUSIONS:

    Apart from overdose and addiction itself, the harmful consequences of injecting morphine tablets come from the insoluble particles from the tablets and microbial contamination. These harmful components can be substantially reduced by passing the injection through a sterilizing (0.22 microm) filter. To prevent the filter from blocking, a preliminary coarse filter (such as a cigarette filter) should be used first. The filters retain some of the dose, but this can be recovered by following filtration with one or two rinses with 1 ml water. Although filtration can reduce the non-pharmacological harmful consequences of injecting tablets, this remains an unsafe practice due to skin and environmental contamination by particles and microorganisms, and the risks of blood-borne infections from sharing injecting equipment.

    PMID:
    20025779
    [PubMed]
    PMCID:
    PMC2803777
    Free PMC Article

    Images from this publication.See all images (7) Free text

    Figure 1
    Figure 3
    Figure 5
    Figure 7
    Figure 2
    Figure 4
    Figure 6

      Supplemental Content

      Icon for BioMed Central Icon for PubMed Central

      Save items

      loading

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk