    Radiother Oncol. 2010 Mar;94(3):334-8. Epub 2009 Dec 18.

    Unilateral radiotherapy for tonsil cancer: potential dose distribution optimization with a simple two-field intensity-modulated radiation therapy beam arrangement.

    Source

    Department of Radiation Oncology, Geneva University Hospital, Geneva, Switzerland. Thomas.Zilli@hcuge.ch

    Abstract

    BACKGROUND AND PURPOSE:

    To evaluate the feasibility and dosimetric optimization potential of a unilateral two-field intensity-modulated radiotherapy (IMRT) technique in the curative treatment of lateralized tonsil cancer.

    MATERIALS AND METHODS:

    Six patients with lateralized tonsillar carcinoma were treated unilaterally with a two-field IMRT technique (oblique-anterior and oblique-posterior fields, with or without collimator and couch rotation). Alternative IMRT plans using seven non-opposed coplanar fields were compared with the two-field plans for each patient.

    RESULTS:

    Planning target volume (PTV) coverage was excellent with the two-field technique, using a relatively low number of monitor units (MU) (median, 441; range, 309-550). Dose constraints were respected for all organs at risk (OAR). Mean doses to contralateral parotid and submandibular glands were 3.9 and 17.7 Gy, respectively. Seven-field IMRT provided similar PTV coverage, with statistically significant better dose homogeneity and conformality. However, the mean delivered dose to the contralateral parotid (3.9 vs. 9.0 Gy, p=0.001) as well as the mean number of MU (437 vs. 814, p=0.002) and consequently machine time were lower with two-field IMRT.

    CONCLUSIONS:

    Unilateral two-field IMRT is a simple and feasible technique providing excellent tumor coverage and optimal OAR sparing while reducing the number of MU and treatment time.

    (c) 2009 Elsevier Ireland Ltd. All rights reserved.