    Hum Reprod. 2010 Feb;25(2):354-9. Epub 2009 Dec 1.

    Bleeding pattern and safety of consecutive use of the levonorgestrel-releasing intrauterine system (LNG-IUS)--a multicentre prospective study.

    Source

    Department of Obstetrics and Gynaecology, Karolinska University Hospital, Stockholm, Sweden.

    Abstract

    BACKGROUND:

    The LNG-IUS has increasingly been used for contraception, treatment of menorrhagia and endometrial protection during hormone replacement therapy since mid-1990s. Thus, many women use the LNG-IUS consecutively. However, published data on the bleeding pattern regarding consecutive use of the LNG-IUS is scarce.

    METHODS:

    We performed a prospective 15-month multicentre study on the bleeding profile, removal and insertion procedures and safety of the second LNG-IUS in fertile-aged women who had used their first LNG-IUS between 4 years 3 months and 4 years 9 months and who opted for the insertion of a second IUS immediately after removal of the first IUS. Bleeding data were reported descriptively starting from the last 90 days of the first IUS use and continuing for up to 1 year.

    RESULTS:

    Of the 234 subjects screened, 204 (87%) entered the trial. The median number of bleeding/spotting days during the last 90 days of the first LNG-IUS was 7 (25 and 75% percentiles 0 and 15). Due to bleeding associated with the insertion procedure, this increased to 8 days (4 and 18) during the first 90-day reference period, thereafter decreasing to 4 (0 and 10) days during the second to fourth reference periods. Only one expulsion and no pregnancies, pelvic inflammatory diseases or perforations occurred. A total of 12 subjects (5.9%) prematurely discontinued the study: five due to an adverse event and seven due to other reasons (inclusive of loss to follow-up).

    CONCLUSIONS:

    This study confirms the favourable bleeding profile and safety of consecutive use of the LNG-IUS.

    PMID:
    19955104
    [PubMed - indexed for MEDLINE]