Med Dosim. 2010 Winter;35(4):297-303. doi: 10.1016/j.meddos.2009.09.004. Epub 2009 Oct 30.

On the use of hyperpolarized helium MRI for conformal avoidance lung radiotherapy.

Author information

  • 1Department of Human Oncology, University of Wisconsin, Madison, 53792, USA.

Abstract

We wanted to illustrate the feasibility of using hyperpolarized helium magnetic resonance imaging (HPH-MRI) to obtain functional information that may assist in improving conformal avoidance of ventilating lung tissue during thoracic radiotherapy. HPH-MRI images were obtained from a volunteer patient and were first fused with a proton density-weighted (PD(w)) MRI to provide corresponding anatomic detail; they were then fused with the treatment planning computed tomography scan of a patient from our treatment planning database who possessed equivalent thoracic dimensions. An optimized treatment plan was then generated using the TomoTherapy treatment planning system, designating the HPH-enhancing regions as ventilation volume (VV). A dose-volume histogram compares the dosimetry of the lungs as a paired organ, the VV, and the lungs minus the VV. The clinical consequences of these changes was estimated using a bio-effect model, the parallel architecture model, or the local damage (f(dam)) model. Model parameters were chosen from published studies linking the incidence of grade 3+ pneumonitis, with the dose and volume irradiated. For two hypothetical treatment plans of 60 Gy in 30 fractions delivered to a right upper-lobe lung mass, one using and one ignoring the VV as an avoidance structure, the mean normalized total dose (NTD(mean)) values for the lung subvolumes were: lungs = 12.5 Gy₃ vs. 13.52 Gy₃, VV = 9.94 Gy₃ vs. 13.95 Gy₃, and lungs minus VV = 16.69 Gy₃ vs. 19.16 Gy₃. Using the f(dam) values generated from these plans, one would predict a reduction of the incidence of grade 3+ radiation pneumonitis from 12%-4% when compared with a conventionally optimized plan. The use of HPH-MRI to identify ventilated lung subvolumes is feasible and has the potential to be incorporated into conformal avoidance treatment planning paradigms. A prospective clinical study evaluating this imaging technique is being developed.

Copyright © 2010 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

PMID:
19944585
[PubMed - indexed for MEDLINE]
PMCID:
PMC2975877
Free PMC Article

Images from this publication.See all images (4)Free text

Figure 1
Figure 2
Figure 3
Figure 4
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Elsevier Science Icon for PubMed Central
    Loading ...
    Write to the Help Desk