    Radiat Oncol. 2009 Oct 25;4:48.

    A fast radiotherapy paradigm for anal cancer with volumetric modulated arc therapy (VMAT).

    Stieler F, Wolff D, Lohr F, Steil V, Abo-Madyan Y, Lorenz F, Wenz F, Mai S.

    Department of Radiation Oncology, University Medical Center Mannheim, University Heidelberg, Germany. florian.stieler@umm.de

    Abstract

    BACKGROUND/PURPOSE: Radiotherapy (RT) volumes for anal cancer are large and of moderate complexity when organs at risk (OAR) such as testis, small bowel and bladder are at least partially to be shielded. Volumetric intensity modulated arc therapy (VMAT) might provide OAR-shielding comparable to step-and-shoot intensity modulated radiotherapy (IMRT) for this tumor entity with better treatment efficiency.

    MATERIALS AND METHODS: Based on treatment planning CTs of 8 patients, we compared dose distributions, comformality index (CI), homogeneity index (HI), number of monitor units (MU) and treatment time (TTT) for plans generated for VMAT, 3D-CRT and step-and-shoot-IMRT (optimized based on Pencil Beam (PB) or Monte Carlo (MC) dose calculation) for typical anal cancer planning target volumes (PTV) including inguinal lymph nodes as usually treated during the first phase (0-36 Gy) of a shrinking field regimen.

    RESULTS: With values of 1.33 +/- 0.21/1.26 +/- 0.05/1.3 +/- 0.02 and 1.39 +/- 0.09, the CI's for IMRT (PB-Corvus/PB-Hyperion/MC-Hyperion) and VMAT are better than for 3D-CRT with 2.00 +/- 0.16. The HI's for the prescribed dose (HI36) for 3D-CRT were 1.06 +/- 0.01 and 1.11 +/- 0.02 for VMAT, respectively and 1.15 +/- 0.02/1.10 +/- 0.02/1.11 +/- 0.08 for IMRT (PB-Corvus/PB-Hyperion/MC-Hyperion). Mean TTT and MU's for 3D-CRT is 220s/225 +/- 11MU and for IMRT (PB-Corvus/PB-Hyperion/MC-Hyperion) is 575s/1260 +/- 172MU, 570s/477 +/- 84MU and 610s748 +/- 193MU while TTT and MU for two-arc-VMAT is 290s/268 +/- 19MU.

    CONCLUSION: VMAT provides treatment plans with high conformity and homogeneity equivalent to step-and-shoot-IMRT for this mono-concave treatment volume. Short treatment delivery time and low primary MU are the most important advantages.

    PMID: 19852856 [PubMed - indexed for MEDLINE]PMCID: PMC2774855Free PMC Article