Antimicrob Agents Chemother. 2009 Dec;53(12):5145-9. doi: 10.1128/AAC.00718-09. Epub 2009 Oct 5.

Novel antiseptic urinary catheters for prevention of urinary tract infections: correlation of in vivo and in vitro test results.

Author information

  • 1Department of Infectious Diseases, Infection Control and Employee Health, University of Texas M D Anderson Cancer Center, Houston, TX 77030, USA. rhachem@mdanderson.org

Abstract

Urinary catheters are widely used for hospitalized patients and are often associated with high rates of urinary tract infection. We evaluated in vitro the antiadherence activity of a novel antiseptic Gendine-coated urinary catheter against several multidrug-resistant bacteria. Gendine-coated urinary catheters were compared to silver hydrogel-coated Foley catheters and uncoated catheters. Bacterial biofilm formation was assessed by quantitative culture and scanning electron microscopy. These data were further correlated to an in vivo rabbit model. We challenged 31 rabbits daily for 4 days by inoculating the urethral meatus with 1.0 x 10(9) CFU streptomycin-resistant Escherichia coli per day. In vitro, Gendine-coated urinary catheters reduced the CFU of all organisms tested for biofilm adherence compared with uncoated and silver hydrogel-coated catheters (P < 0.004). Scanning electron microscopy analysis showed that a thick biofilm overlaid the control catheter and the silver hydrogel-coated catheters but not the Gendine-coated urinary catheter. Similar results were found with the rabbit model. Bacteriuria was present in 60% of rabbits with uncoated catheters and 71% of those with silver hydrogel-coated catheters (P < 0.01) but not in those with Gendine-coated urinary catheters. No rabbits with Gendine-coated urinary catheters had invasive bladder infections. Histopathologic assessment revealed no differences in toxicity or staining. Gendine-coated urinary catheters were more efficacious in preventing catheter-associated colonization and urinary tract infections than were silver hydrogel-coated Foley catheters and uncoated catheters.

PMID:
19805562
[PubMed - indexed for MEDLINE]
PMCID:
PMC2786341
Free PMC Article

Images from this publication.See all images (1)Free text

FIG. 1.
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Icon for HighWire Icon for PubMed Central
    Loading ...
    Write to the Help Desk