    Anal Chem. 2009 Oct 15;81(20):8538-44. doi: 10.1021/ac9014947.

    Variability analysis of human plasma and cerebral spinal fluid reveals statistical significance of changes in mass spectrometry-based metabolomics data.

    Source

    Department of Molecular Biology and The Center for Mass Spectrometry, The Scripps Research Institute, 10550 North Torrey Pines Road, La Jolla, California 92037, USA.

    Abstract

    Analytical and biological variability are issues of central importance to human metabolomics studies. Here both types of variation are examined in human plasma and cerebrospinal fluid (CSF) using a global liquid chromatography/mass spectrometry (LC/MS) metabolomics strategy. The platform shows small analytical variation with a median coefficient of variation (CV) of 15-16% for both plasma and CSF sample matrixes when the integrated area of each peak in the mass spectra is considered. Analysis of biological variation shows that human CSF has a median CV of 35% and plasma has a median CV of 46%. To understand the difference in CV between the biofluids, we compared plasma and CSF independently obtained from different healthy humans. Additionally, we analyzed another group of patients from whom we compared matched CSF and plasma (plasma and CSF obtained from the same human subject). A similar number of features was observed in both biofluids, although the majority of features appeared with greater intensity in plasma. More than a dozen metabolites shared between the human CSF and plasma metabolomes were identified based on accurate mass measurements, retention times, and MS/MS spectra. The fold change in these metabolites was consistent with the median biological CV determined for all peaks. The measured median biological CV together with analysis of intragroup variation of healthy individuals suggests that fold changes above 2 in metabolomics studies investigating plasma or CSF are statistically relevant with respect to the inherent variability of a healthy control group. These data demonstrate the reproducibility of the global metabolomics platform using LC/MS and reveal the robustness of the approach for biomarker discovery.

    PMID:
    19764780
    [PubMed - indexed for MEDLINE]
    PMCID:
    PMC3058611
    Free PMC Article

    Images from this publication.See all images (6)Free text

    Figure 1
    Figure 2
    Figure 3
    Figure 4
    Figure 5
    Figure 6

      Supplemental Content

      Icon for American Chemical Society Icon for PubMed Central

      Save items

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk