    J Nucl Med. 2009 Sep;50(9):1518-24.

    Whole-body dosimetry for individualized treatment planning of 131I-MIBG radionuclide therapy for neuroblastoma.

    Buckley SE, Chittenden SJ, Saran FH, Meller ST, Flux GD.

    Department of Physics, Royal Marsden NHS Foundation Trust, Sutton, Surrey, United Kingdom.

    The aims of this study were to examine the relationship between whole-body absorbed dose and hematologic toxicity and to assess the most accurate method of delivering a prescribed whole-body absorbed dose in (131)I-metaiodobenzylguanidine ((131)I-MIBG) therapy for neuroblastoma. METHODS: A total of 20 children (1-12 y), 5 adolescents (13-17 y), and 1 adult (20 y) with stage 3 or 4 neuroblastoma were treated to a prescribed whole-body absorbed dose, which in most cases was 2 Gy. Forty-eight administrations of (131)I-MIBG were given to the 26 patients, ranging in activity from 1,759 to 32,871 MBq. For 30 administrations, sufficient data were available to assess the effect of whole-body absorbed dose on hematologic toxicity. Comparisons were made between the accuracy with which a whole-body absorbed dose could be predicted using a pretherapy tracer study and the patient's most recent previous therapy. The whole-body absorbed dose that would have been delivered if the administered activity was fixed (7,400 MBq) or determined using a weight-based formula (444 MBq.kg(-1)) was also estimated. RESULTS: The mean whole-body absorbed dose for patients with grade 4 Common Terminology Criteria for Adverse Events (CTCAE) neutropenia after therapy was significantly higher than for those with grade 1 CTCAE neutropenia (1.63 vs. 0.90 Gy; P = 0.05). There was no correlation between administered activity and hematologic toxicity. Absorbed whole-body doses predicted from previous therapies were within +/-10% for 70% of the cases. Fixed-activity administrations gave the largest range in whole-body absorbed dose (0.30-3.11 Gy). CONCLUSION: The results indicate that even in a highly heterogeneous and heavily pretreated patient population, a whole-body absorbed dose can be prescribed accurately and is a more accurate predictor of hematologic toxicity than is administered activity. Therefore, a whole-body absorbed dose can be used to deliver accurate and reproducible (131)I-MIBG therapy on a patient-specific basis.

    PMID: 19713562 [PubMed - indexed for MEDLINE]

    Supplemental Content

    Click here to read