Opt Lett. 2009 May 15;34(10):1513-5.

Development of 1.6 microm continuous-wave modulation hard-target differential absorption lidar system for CO2 sensing.

Author information

  • 1Information Technology R&D Center, Mitsubishi Electric Corporation, Japan. Kameyama.Shumpei@dn.MitsubishiElectric.co.jp

Abstract

We have demonstrated the 1.6 mum cw modulation hard-target differential absorption lidar system for CO(2) sensing. In this system, ON and OFF wavelength laser lights are intensity modulated with cw signals. Received lights of the two wavelengths from the hard target are discriminated by modulation frequencies in the electrical signal domain. The optical circuit is fiber based, and this makes the system compact and reliable. It is shown that a stable CO(2) concentration measurement corresponding to a fluctuation of 4 ppm (rms) (ppm is parts per million) has been achieved in 32 s measurement intervals and the 1 km path.

PMID:
19448805
[PubMed]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Optical Society of America
    Loading ...
    Write to the Help Desk