Photochem Photobiol. 2009 Jul-Aug;85(4):1004-10. doi: 10.1111/j.1751-1097.2009.00540.x. Epub 2009 Mar 20.

Analysis of compact fluorescent lights for use by patients with photosensitive conditions.

Author information

  • 1Philadelphia V.A. Hospital, and Department of Dermatology, University of Pennsylvania, Philadelphia, PA, USA.

Abstract

Ultraviolet radiation (UVR) is hazardous to patients with photosensitive skin disorders, such as lupus erythematosus, xeroderma pigmentosum and skin cancer. As such, these patients are advised to minimize their exposure to UVR. Classically, this is accomplished through careful avoidance of sun exposure and artificial tanning booths. Indoor light bulbs, however, are generally not considered to pose significant UVR hazard. We sought to test this notion by measuring the UV emissions of 19 different compact fluorescent light bulbs. The ability to induce skin damage was assessed with the CIE erythema action spectrum, ANSI S(lambda) generalized UV hazard spectrum and the CIE photocarcinogenesis action spectrum. The results indicate that there is a great deal of variation amongst different bulbs, even within the same class. Although the irradiance of any given bulb is low, the possible daily exposure time is rather lengthy. This results in potential daily UVR doses ranging from 0.1 to 625 mJ cm(-2), including a daily UVB (290-320 nm) dose of 0.01 to 15 mJ cm(-2). Because patients are exposed continually over long time frames, this could lead to significant cumulative damage. It would therefore be prudent for patients to use bulbs with the lowest UV irradiance.

PMID:
19320850
[PubMed - indexed for MEDLINE]
PMCID:
PMC2868278
Free PMC Article

Images from this publication.See all images (4)Free text

Figure 1
Figure 2
Figure 3
Figure 4
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Icon for Blackwell Publishing Icon for PubMed Central
    Loading ...
    Write to the Help Desk