    Lancet. 2009 Mar 14;373(9667):897-910.

    A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods.

    Serruys PW, Ormiston JA, Onuma Y, Regar E, Gonzalo N, Garcia-Garcia HM, Nieman K, Bruining N, Dorange C, Miquel-Hébert K, Veldhof S, Webster M, Thuesen L, Dudek D.

    Thorax Center, Erasmus Medical Center, Rotterdam, Netherlands.

    Comment in:

    BACKGROUND: Drug-eluting metallic coronary stents predispose to late stent thrombosis, prevent late lumen vessel enlargement, hinder surgical revascularisation, and impair imaging with multislice CT. We assessed the safety of the bioabsorbable everolimus-eluting stent (BVS). METHODS: 30 patients with a single de-novo coronary artery lesion were followed up for 2 years clinically and with multiple imaging methods: multislice CT, angiography, intravascular ultrasound, derived morphology parameters (virtual histology, palpography, and echogenicity), and optical coherence tomography (OCT). FINDINGS: Clinical data were obtained from 29 of 30 patients. At 2 years, the device was safe with no cardiac deaths, ischaemia-driven target lesion revascularisations, or stent thromboses recorded, and only one myocardial infarction (non-Q wave). 18-month multislice CT (assessed in 25 patients) showed a mean diameter stenosis of 19% (SD 9). At 2-year angiography, the in-stent late loss of 0.48 mm (SD 0.28) and the diameter stenosis of 27% (11) did not differ from the findings at 6 months. The luminal area enlargement on OCT and intravascular ultrasound between 6 months and 2 years was due to a decrease in plaque size without change in vessel size. At 2 years, 34.5% of strut locations presented no discernible features by OCT, confirming decreases in echogenicity and in radiofrequency backscattering; the remaining apparent struts were fully apposed. Additionally, vasomotion occurred at the stented site and adjacent coronary artery in response to vasoactive agents. INTERPRETATION: At 2 years after implantation the stent was bioabsorbed, had vasomotion restored and restenosis prevented, and was clinically safe, suggesting freedom from late thrombosis. Late luminal enlargement due to plaque reduction without vessel remodelling needs confirmation.

    PMID: 19286089 [PubMed - indexed for MEDLINE]

    Supplemental Content

    Click here to read Click here to read Click here to read Click here to read Click here to read

    Patient drug information

    • Sirolimus (Rapamune®)

      Sirolimus is used in combination with other medications to prevent rejection of kidney transplants. Sirolimus is in a class of medications called immunosuppressants. It works by suppressing the body's immune system.

    • Everolimus (Afinitor®)

      Everolimus is used to treat advanced renal cell carcinoma (RCC; cancer that begins in the kidneys) that has already been treated unsuccessfully with other medications. Everolimus is in a class of medications called kinas...