    J Am Acad Audiol. 2008 Jul-Aug;19(7):548-56.

    A comparison of two word-recognition tasks in multitalker babble: Speech Recognition in Noise Test (SPRINT) and Words-in-Noise Test (WIN).

    Source

    VA Medical Center, Audiology (126), Mountain Home, TN 37684, USA. RICHARD.WILSON2@VA.GOV

    Abstract

    BACKGROUND:

    The Speech Recognition in Noise Test (SPRINT) is a word-recognition instrument that presents the 200 Northwestern University Auditory Test No. 6 (NU-6) words binaurally at 50 dB HL in a multitalker babble at a 9 dB signal-to-noise ratio (S/N) (Cord et al, 1992). The SPRINT was developed by and used by the Army as a more valid predictor of communication abilities (than pure-tone thresholds or word-recognition in quiet) for issues involving fitness for duty from a hearing perspective of Army personnel. The Words-in-Noise test (WIN) is a slightly different word-recognition task in a fixed level multitalker babble with 10 NU-6 words presented at each of 7 S/N from 24 to 0 dB S/N in 4 dB decrements (Wilson, 2003; Wilson and McArdle, 2007). For the two instruments, both the babble and the speakers of the words are different. The SPRINT uses all 200 NU-6 words, whereas the WIN uses a maximum of 70 words.

    PURPOSE:

    The purpose was to compare recognition performances by 24 young listeners with normal hearing and 48 older listeners with sensorineural hearing on the SPRINT and WIN protocols.

    RESEARCH DESIGN:

    A quasi-experimental, mixed model design was used.

    STUDY SAMPLE:

    The 24 young listeners with normal hearing (19 to 29 years, mean = 23.3 years) were from the local university and had normal hearing (< or = 20 dB HL; American National Standards Institute, 2004) at the 250-8000 Hz octave intervals. The 48 older listeners with sensorineural hearing loss (60 to 82 years, mean = 69.9 years) had the following inclusion criteria: (1) a threshold at 500 Hz between 15 and 30 dB HL, (2) a threshold at 1000 Hz between 20 and 40 dB HL, (3) a three-frequency puretone average (500, 1000, and 2000 Hz) of < or = 40 dB HL, (4) word-recognition scores in quiet > or = 40%, and (5) no history of middle ear or retrocochlear pathology as determined by an audiologic evaluation.

    DATA COLLECTION AND ANALYSIS:

    The speech materials were presented bilaterally in the following order: (1) the SPRINT at 50 dB HL, (2) two half lists of NU-6 words in quiet at 60 dB HL and 80 dB HL, and (3) the two 35-word lists of the WIN materials with the multitalker babble fixed at 60 dB HL. Data collection occurred during a 40-60 minute session. Recognition performances on each stimulus word were analyzed.

    RESULTS:

    The listeners with normal hearing obtained 92.5% correct on the SPRINT with a 50% point on the WIN of 2.7 dB S/N. The listeners with hearing loss obtained 65.3% correct on the SPRINT and a WIN 50% point at 12.0 dB S/N. The SPRINT and WIN were significantly correlated (r = -0.81, p < .01), indicating that the SPRINT had good concurrent validity. The high-frequency, pure-tone average (1000, 2000, 4000 Hz) had higher correlations with the SPRINT, WIN, and NU-6 in quiet than did the traditional three-frequency pure-tone average (500, 1000, 2000 Hz).

    CONCLUSIONS:

    Graphically and numerically the SPRINT and WIN were highly related, which is indicative of good concurrent validity of the SPRINT.