Display Settings:

Format

Send to:

Choose Destination
    AJR Am J Roentgenol. 2009 Feb;192(2):341-51.

    False-negative diagnoses at stereotactic vacuum-assisted needle breast biopsy: long-term follow-up of 1,280 lesions and review of the literature.

    Source

    Department of Radiology, Palo Alto Medical Clinic, Palo Alto, CA, USA. JackmanR@Gmail.com

    Abstract

    OBJECTIVE:

    The purpose of this study was to determine retrospectively the frequency and causes of false-negative diagnoses of lesions evaluated with percutaneous stereotactic biopsy performed with vacuum-assisted probes with the patient prone on a biopsy table.

    MATERIALS AND METHODS:

    The records of 1,152 women (median age, 55 years; range, 31-94 years) with 1,280 lesions consecutively biopsied with 14-gauge (n = 159) or 11-gauge (n = 1,121) vacuum probes were reviewed retrospectively. The histologic diagnoses were malignant (n = 489), high-risk (n = 117), and benign (n = 674) lesions. Benign lesions were evaluated with repeated biopsy (n = 46) or mammographic follow-up for 24 months or longer (n = 506) or less than 24 months (n = 57). In 65 cases (10% of all benign lesions), follow-up was not performed. Fisher's exact tests were used to correlate patient, mammographic, and biopsy variables with false-negative diagnoses.

    RESULTS:

    Of 508 lesions with a final diagnosis of malignancy, the initial needle biopsy diagnosis was malignant (n = 489), high-risk (n = 14), or benign (n = 5) lesion. The five false-negative diagnoses were related to gauge of the biopsy probe and specimen radiographic findings regarding calcifications but were not related to lesion type. False-negative diagnoses were made in 4.4% (three of 68) of cases in which 14-gauge vacuum biopsy was performed and in 0.45% (two of 440) of cases in which 11-gauge vacuum biopsy was performed (p = 0.019). False-negative diagnoses were made in 25% (one of four) of cases in which specimen radiographs showed no calcifications and 0.67% (two of 300) of cases in which they did show calcifications (p = 0.0390). False-negative diagnoses were made in 1.2% (three of 248) of cases of calcification lesions and 0.8% (two of 260) of cases of mass lesions (p = 0.679).

    CONCLUSION:

    False-negative findings at stereotactic biopsy were least common with 11-gauge probes and were similar in frequency for calcifications and masses.

    PMID:
    19155393
    [PubMed - indexed for MEDLINE]
    Free full text

      Supplemental Content

      Icon for HighWire Press

      Save items

      loading

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk