Format

Send to:

Choose Destination
See comment in PubMed Commons below
Plast Reconstr Surg. 2009 Jan;123(1):1-6; discussion 107-8. doi: 10.1097/PRS.0b013e3181904bff.

AlloDerm versus DermaMatrix in immediate expander-based breast reconstruction: a preliminary comparison of complication profiles and material compliance.

Author information

  • 1Department of Plastic Surgery, University of Texas Southwestern Medical Center, Dallas, Texas 75390-9132, USA.

Abstract

BACKGROUND:

Allogenic acellular dermal matrix can be used in single-stage, expander-based immediate and delayed breast reconstructions to provide inferolateral prosthesis coverage and reconstruction of the inframammary fold. Two allogenic dermal matrix products currently available, AlloDerm and DermaMatrix, differ in method of storage, cost, and intraoperative preparation. The purpose of this study was to determine, first, whether there are any significant differences in the rates of postoperative complications, material compliance, or capsule characteristics; and second, if differences are present, whether they had any impact on final outcome.

METHODS:

After institutional review board approval, a retrospective analysis of prospectively collected data of 30 patients (50 breasts) who underwent immediate expander-based breast reconstructions using either AlloDerm (n = 25) or DermaMatrix (n = 25) dermal substitutes was performed. Primary endpoints were (1) incidence of seroma, (2) wound infection, (3) number of days requiring drains, (4) rate of tissue expansion, (5) final expanded volume, (6) final implant volume, and (7) neovascularization.

RESULTS:

The mean follow-up was 6.7 months. During this time, no significant differences in the complication profile were found between the two groups. Both dermal substitutes were found to be well incorporated, with evidence of neovascularization, on histologic examination.

CONCLUSIONS:

This study demonstrated no significant differences in the rate of complications or material compliance. The total complication rate was 4 percent, with seroma and wound infection being the most common complications. The authors' preliminary findings indicate no significant difference between implant/expander-based reconstructions using AlloDerm and those using DermaMatrix.

PMID:
19116505
[PubMed - indexed for MEDLINE]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons