Display Settings:

Format

Send to:

Choose Destination
    Anesthesiology. 2009 Jan;110(1):150-4.

    Comparison of continuous infusion versus automated bolus for postoperative patient-controlled analgesia with popliteal sciatic nerve catheters.

    Source

    University of Santiago de Compostela, and Department of Anesthesiology, Hospital Clínico Universitario de Santiago, Spain. manutabo@yahoo.es

    Abstract

    BACKGROUND:

    This investigation was designed to compare a new methodology of automated regular bolus with a continuous infusion of local anesthetic for continuous popliteal sciatic block; both regimens were combined with patient-controlled analgesia (PCA).

    METHODS:

    Fifty patients undergoing hallux valgus repair were randomly allocated to receive an infusion of 0.125% levobupivacaine administered through a popliteal catheter as an automated regular bolus (n = 25) or as a continuous infusion (n = 25), both combined with PCA. Postoperative pain scores, incremental doses delivered by the PCA, local anesthetic consumed per hour, and the need for rescue tramadol analgesia were recorded.

    RESULTS:

    Both dosing regimens provided similar postoperative analgesia. Consumption of local anesthetic (5.14 ml/h, 5-5.75 ml/h) and dose request from the PCA (1, 0-5.4) was lower in the automated bolus group as compared to the continuous infusion group (5.9 ml/h, 5.05-7.8 ml/h; doses by PCA: 6.5, 0-20.5; P < 0.05). The need for rescue tramadol was similar in the two groups.

    CONCLUSION:

    In continuous popliteal sciatic block, local anesthetic administered as an automated regular bolus in conjunction with PCA provided similar pain relief as a continuous infusion technique combined with PCA; however, the new dosing regimen reduced the need for additional PCA and the overall consumption of local anesthetic.

    PMID:
    19104182
    [PubMed - indexed for MEDLINE]