    Talanta. 1987 Mar;34(3):367-8.

    Spectrophotometric determination of cobalt in iron-, cobalt- and nickel-base alloys.

    Source

    Defence Metallurgical Research Laboratory. P.O. Kanchanbagh, Hyderabad 500 258, India.

    Abstract

    A spectrophotometric method has been developed for the accurate determination of cobalt at milligram level, based on oxidation of the cobalt(II)-EDTA complex with gold(III) chloride at pH 4.0-6.5 and 100 degrees and measurement of the absorbance of the resultant violet cobalt(III)-EDTA complex at 535 nm. The precision is not affected by the presence of several metal ions; including coloured ones such as Cu(II), Ni(II) and Fe(III). However, chromium(III) interferes since it also forms a violet complex with EDTA, but can be removed by separation with pyridine. Practical application of the method is illustrated by the determination of cobalt in alloys based on iron, cobalt and nickel. Over the cobalt range 8-52% the error ranges from 0.1 to 0.3%.