Display Settings:

Format

Send to:

Choose Destination
See comment in PubMed Commons below
Int J Radiat Oncol Biol Phys. 2008 Aug 1;71(5):1526-36. doi: 10.1016/j.ijrobp.2008.04.018.

A deliverable four-dimensional intensity-modulated radiation therapy-planning method for dynamic multileaf collimator tumor tracking delivery.

Author information

  • 1Department of Radiation Oncology, Virginia Commonwealth University, Richmond, VA, USA. ysuh@stanford.edu

Abstract

PURPOSE:

To develop a deliverable four-dimensional (4D) intensity-modulated radiation therapy (IMRT) planning method for dynamic multileaf collimator (MLC) tumor tracking delivery.

METHODS AND MATERIALS:

The deliverable 4D IMRT planning method involves aligning MLC leaf motion parallel to the major axis of target motion and translating MLC leaf positions by the difference in the target centroid position between respiratory phases of the 4D CT scan. This method ignores nonlinear respiratory motion and deformation. A three-dimensional (3D) optimal method whereby an IMRT plan on each respiratory phase of the 4D CT scan was independently optimized was used for comparison. For 12 lung cancer patient 4D CT scans, individual phase plans and deformable dose-summed 4D plans using the two methods were created and compared.

RESULTS:

For each of the individual phase plans, the deliverable method yielded similar isodose distributions and dose-volume histograms. The deliverable and 3D optimal methods yielded statistically equivalent dose-volume metrics for both individual phase plans and 4D plans (p > 0.05 for all metrics compared). The deliverable method was affected by 4D CT artifacts in one case. Both methods were affected by high vector field variations from deformable registration.

CONCLUSIONS:

The deliverable method yielded similar dose distributions for each of the individual phase plans and statistically equivalent dosimetric values compared with the 3D optimal method, indicating that the deliverable method is dosimetrically robust to the variations of fractional time spent in respiratory phases on a given 4D CT scan. Nonlinear target motion and deformation did not cause significant dose discrepancies.

PMID:
18640500
[PubMed - indexed for MEDLINE]
PMCID:
PMC2600678
Free PMC Article

Images from this publication.See all images (7)Free text

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Icon for Elsevier Science Icon for PubMed Central
    Loading ...
    Write to the Help Desk