Display Settings:

Format

Send to:

Choose Destination
    J Cataract Refract Surg. 2008 Jun;34(6):1044-6.

    Descemet-stripping endothelial keratoplasty: improvement in vision following replacement of a healthy endothelial graft.

    Source

    Spectrum Eye Physicians, San Jose, California 95129, USA. eschen37@hotmail.com

    Abstract

    We describe a case of endothelial graft exchange in a patient who had inadequate vision without a clinically identifiable cause following Descemet-stripping endothelial keratoplasty (DSEK). The initial DSEK was performed with a hand-dissected donor, and the replacement graft was prepared with an automated microkeratome. The best spectacle-corrected visual acuity (BSCVA) improved from 20/50 before replacement to 20/25 after replacement. Although DSEK provides rapid recovery of excellent vision, few patients achieve a BSCVA of 20/20. Some have substandard vision with no clinically identifiable cause. This case demonstrates that replacing a hand-prepared graft with an automated microkeratome-prepared graft may improve vision in patients with no identifiable cause for visual loss.

    PMID:
    18499018
    [PubMed - indexed for MEDLINE]

      Supplemental Content

      Icon for Elsevier Science

      Save items

      loading

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk