Crit Care. 2008;12(3):R70. doi: 10.1186/cc6908. Epub 2008 May 20.

Randomized trial comparing daily interruption of sedation and nursing-implemented sedation algorithm in medical intensive care unit patients.

Author information

  • 1Pulmonary and Critical Care Division, Department of Internal Medicine, School of Medicine, Virginia Commonwealth University, PO Box 980050, Richmond, VA 23298-0050, USA. mdewit@mcvh-vcu.edu

Abstract

INTRODUCTION:

Daily interruption of sedation (DIS) and sedation algorithms (SAs) have been shown to decrease mechanical ventilation (MV) duration. We conducted a randomized study comparing these strategies.

METHODS:

Mechanically ventilated adults 18 years old or older in the medical intensive care unit (ICU) were randomly assigned to DIS or SA. Exclusion criteria were severe neurocognitive dysfunction, administration of neuromuscular blockers, and tracheostomy. Study endpoints were total MV duration and 28-day ventilator-free survival.

RESULTS:

The study was terminated prematurely after 74 patients were enrolled (DIS 36 and SA 38). The two groups had similar age, gender, racial distribution, Acute Physiology and Chronic Health Evaluation II score, and reason for MV. The Data Safety Monitoring Board convened after DIS patients were found to have higher hospital mortality; however, no causal connection between DIS and increased mortality was identified. Interim analysis demonstrated a significant difference in primary endpoint, and study termination was recommended. The DIS group had longer total duration of MV (median 6.7 versus 3.9 days; P = 0.0003), slower improvement of Sequential Organ Failure Assessment over time (0.70 versus 0.23 units per day; P = 0.025), longer ICU length of stay (15 versus 8 days; P < 0.0001), and longer hospital length of stay (23 versus 12 days; P = 0.01).

CONCLUSION:

In our cohort of patients, the use of SA was associated with reduced duration of MV and lengths of stay compared with DIS. Based on these results, DIS may not be appropriate in all mechanically ventilated patients.

TRIAL REGISTRATION:

ClinicalTrials.gov NCT00205517.

PMID:
18492267
[PubMed - indexed for MEDLINE]
PMCID:
PMC2481461
Free PMC Article

Images from this publication.See all images (4)Free text

Figure 1
Figure 2
Figure 3
Figure 4
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for BioMed Central Icon for PubMed Central
    Loading ...
    Write to the Help Desk