    Interlaboratory comparison of results of an anthrax lethal toxin neutralization assay for assessment of functional antibodies in multiple species.

    Source

    Precision Bioassay, Burlington, Vermont, USA.

    Abstract

    The anthrax lethal toxin neutralization assay (TNA) will likely be used to correlate the protection offered by new anthrax vaccines in animal models to the immunogenicity that will be provided in humans. TNA data are being generated in several different laboratories to measure the immune responses in rabbits, nonhuman primates, and humans. In order to compare data among species and laboratories, a collaborative study was conducted in which 108 samples from the three species were analyzed in seven independent laboratories. Six of the seven laboratories had participated in an interlaboratory technology transfer of the TNA. Analysis of the titration curves generated by samples from each species indicated that the behaviors of the samples from all species were similar; the upper and lower asymptotes and the slopes of the curves were less than 30% divergent from those for human reference material. Dilutional linearity was consistent among samples from each species, with spike to effective dilution at 50% inhibition (ED(50)) slopes of less than 1.2 for all species. Agreement among the laboratories with consensus values was within 10% of the ED(50)s for all samples and within 7.5% of the quotients of the test sample ED(50) and the reference standard ED(50) (NF(50)s) for all samples. The relative standard deviations obtained when data from all laboratories and for all species were combined were 45% for the ED(50)s and 35% for the NF(50)s. These precision data suggest that the NF(50) readout may normalize the values generated by different laboratories. This study demonstrates that the TNA is a panspecies assay that can be performed in several different laboratories with a high degree of quantitative agreement and precision.

    PMID:
    18417668
    [PubMed - indexed for MEDLINE]
    PMCID:
    PMC2446612
    Free PMC Article

    Images from this publication.See all images (5) Free text

    FIG. 1.
    FIG. 3.
    FIG. 5.
    FIG. 2.
    FIG. 4.

      Supplemental Content

      Icon for HighWire Press Icon for PubMed Central

      Save items

      loading

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk