Display Settings:

Format

Send to:

Choose Destination
    Catheter Cardiovasc Interv. 2008 Jun 1;71(7):950-60.

    Carotid artery revascularization in high surgical risk patients with the NexStent and the Filterwire EX/EZ: 1-year results in the CABERNET trial.

    Source

    Department of Neurosurgery, University of Buffalo and Toshiba Stroke Center, Buffalo, New York 14209, USA. lnhbuffns@aol.com

    Abstract

    OBJECTIVE:

    The multicenter, single-arm CABERNET trial evaluated outcomes in high-surgical-risk patients with carotid artery stenosis treated with the NexStent plus FilterWire EX/EZ Emboli Protection System.

    BACKGROUND:

    For patients at high surgical risk, carotid artery stenting (CAS) offers a less invasive alternative to carotid endarterectomy (CEA).

    METHODS:

    The trial enrolled 454 high-surgical-risk patients with carotid stenosis by angiography > or = 50% for symptomatic patients and > or = 60% for asymptomatic patients. The comparator primary endpoint was the 1-year major adverse event (MAE, defined as any death, stroke, or myocardial infarction [MI]) rate. It was compared with a proportionally weighted objective performance criterion (OPC) of 12.1% representative of published CEA results in similar patients plus a prespecified noninferiority margin (delta) of 4%. A second primary endpoint was the composite rate of 30-day MAE plus late (31-365 days) ipsilateral stroke.

    RESULTS:

    Symptoms of carotid stenosis were present in 24.2% of patients; 36.6% of patients were considered high-surgical-risk due to comorbid risk factors and 63.4% due to anatomic risk factors. The rate of 30-day MAE plus late ipsilateral stroke was 4.7% (20/438). The comparator primary endpoint of 1-year MAE was 11.6% (51/438) and was noninferior to the OPC of 12.1% (95% upper confidence interval of 14.5% versus OPC plus delta of 16.1%, P = 0.005). Late ipsilateral stroke was 0.7% and target vessel revascularization at 1 year was 2.4%.

    CONCLUSIONS:

    The CABERNET trial demonstrates that CAS with NexStent and FilterWire is noninferior to (equivalent or better than) traditional CEA at 1 year in high-surgical-risk patients based on historical controls.

    2008 Wiley-Liss, Inc.

    PMID:
    18412236
    [PubMed - indexed for MEDLINE]

      Supplemental Content

      Icon for John Wiley & Sons, Inc.

      Save items

      loading

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk