    Int J Pharm. 2008 May 22;356(1-2):231-8. Epub 2008 Jan 17.

    Pharmacokinetics and pharmacodynamics of exenatide following alternate routes of administration.

    Gedulin BR, Smith PA, Jodka CM, Chen K, Bhavsar S, Nielsen LL, Parkes DG, Young AA.

    Amylin Pharmaceuticals, Inc. 9360 Towne Centre Dr, Ste 110, San Diego, CA 92121, United States.

    Exenatide is a 39-amino acid peptide incretin mimetic approved for adjunctive treatment of type 2 diabetes. It shares several glucoregulatory activities with the mammalian hormone, glucagon-like peptide-1 (GLP-1). In clinical use, subcutaneous exenatide injections demonstrate glucoregulatory and weight loss effects with sustained plasma concentrations in the 50-100 pM range. We investigated the pharmacokinetics of exenatide in normoglycemic rats and biological activity in diabetic db/db mice after delivery to various epithelial surfaces of the intestinal and respiratory tracts. In rats, elimination kinetics were similar for all routes of administration (median k(e) 0.017 min(-1)). Bioavailability (versus intravenous administration) and C(max) per unit dose differed markedly. For gastrointestinal administration, sublingual administration invoked the highest bioavailability (0.37%); in db/db mice, potentially therapeutic concentrations were obtainable. In contrast, intraduodenal bioavailability was low (0.0053%). In regard to respiratory surfaces, bioavailability of intratracheal exenatide was up to 13.6%, and for nasal administration, 1.68%. Both routes of administration produced therapeutic plasma concentrations and glucose-lowering in db/db mice. At high doses, aerosolized exenatide also achieved effective concentrations and glucose-lowering. In summary, the intestinal tract seems to have limited potential as a route of exenatide administration, with sublingual being most promising. In contrast, the respiratory tract appears to be more viable, comparing favorably with the clinically approved subcutaneous route. Despite little optimization of the delivery formulation, exenatide bioavailability compared favorable to that of several commercially available bioactive peptides.

    PMID: 18291606 [PubMed - indexed for MEDLINE]

    Supplemental Content

    Click here to read

    Patient drug information

    • Glucagon (GlucaGen Diagnostic Kit®)

      Glucagon is a hormone produced in the pancreas. Glucagon is used to raise very low blood sugar. Glucagon is also used in diagnostic testing of the stomach and other digestive organs.

    • Exenatide Injection (Byetta®)

      Exenatide is used in combination with metformin, a sulfonylurea, or a thiazolidinedione medication to treat type 2 diabetes (condition in which the body does not use insulin normally and therefore cannot control the amou...