Influence of stent type on hemodynamic depression after carotid artery stent placement

J Vasc Interv Radiol. 2008 Jan;19(1):23-30. doi: 10.1016/j.jvir.2007.09.020.

Abstract

Purpose: To assess the effect of stent type on hypotension and bradycardia after carotid artery stent placement.

Materials and methods: A retrospective analysis on a prospectively maintained database was conducted in 256 patients (126 men; mean age, 71.8 years +/- 8.6; 194 de novo lesions) undergoing carotid artery stent placement between January 1996 and January 2007 by using self-expanding stents. Braided Elgiloy stents (Wallstents) were used in 44 of the 256 patients (17.2%) and slotted-tube nitinol stents were deployed in 212 (82.8%). Bivariate and multivariable logistic regression models were used to determine the influence of stent design on procedural and 24-hour hypotension and bradycardia.

Results: Procedural hemodynamic depression (HD) was encountered in 73 of the 256 patients (28.5%) due to hypotension in 24 (9.4%), bradycardia in 12 (4.7%), or both in 37 (14.5%) patients. Rates of procedural hypotension were 11.3% with nitinol stents and 0% with braided Elgiloy stents (P = .0188). Persistent postprocedural HD occurred in 91 of the 256 patients (35.5%) due to hypotension in 40 patients (15.6%), bradycardia in 23 (9.0%), or both in 28 (10.9%). Within a multivariable analysis adjusted for clinically relevant factors affecting rates of HD, the use of braided Elgiloy stents was associated with a decreased rate of procedural hypotension (odds ratio: 0.165; 95% confidence interval: 0.038, 0.721; P = .017). Procedural hypotension and bradycardia were not correlated to incidence of major adverse events but were associated with an increased duration of hospital stay (P = .0059 and P = .0335, respectively).

Conclusions: Nitinol stents are associated with a higher risk of hypotension as compared to braided Elgiloy stents during carotid artery stent placement.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Alloys
  • Angioplasty, Balloon / adverse effects
  • Angioplasty, Balloon / instrumentation*
  • Bradycardia / epidemiology
  • Bradycardia / etiology*
  • Bradycardia / physiopathology
  • Carotid Stenosis / physiopathology
  • Carotid Stenosis / therapy*
  • Female
  • Hemodynamics*
  • Humans
  • Hypotension / epidemiology
  • Hypotension / etiology*
  • Hypotension / physiopathology
  • Incidence
  • Length of Stay
  • Logistic Models
  • Male
  • Odds Ratio
  • Prosthesis Design
  • Retrospective Studies
  • Risk Assessment
  • Risk Factors
  • Stents*
  • Time Factors
  • Treatment Outcome

Substances

  • Alloys
  • nitinol