Resuscitation. 2008 Apr;77(1):121-6. doi: 10.1016/j.resuscitation.2007.10.016. Epub 2007 Dec 31.

Increasing ventilator surge capacity in disasters: ventilation of four adult-human-sized sheep on a single ventilator with a modified circuit.

Author information

  • 1Department of Emergency Medicine, State University of New York Downstate Medical Center, Brooklyn, NY 11203, United States. LorenzoPaladino@yahoo.com

Abstract

OBJECTIVE:

Recent manmade and natural disasters have focused attention on the need to provide care to large groups of patients. Clinicians, ethicists, and public health officials have been particularly concerned about mechanical ventilator surge capacity and have suggested stock-piling ventilators, rationing, and providing manual ventilation. These possible solutions are complex and variously limited by legal, monetary, physical, and human capital restraints. We conducted a study to determine if a single mechanical ventilator can adequately ventilate four adult-human-sized sheep for 12h.

METHODS:

We utilized a four-limbed ventilator circuit connected in parallel. Four 70-kg sheep were intubated, sedated, administered neuromuscular blockade and placed on a single ventilator for 12h. The initial ventilator settings were: synchronized intermittent mandatory ventilation with 100% oxygen at 16 breaths/min and tidal volume of 6 ml/kg combined sheep weight. Arterial blood gas, heart rate, and mean arterial pressure measurements were obtained from all four sheep at time zero and at pre-determined times over the course of 12h.

RESULTS:

The ventilator and modified circuit successfully oxygenated and ventilated the four sheep for 12h. All sheep remained hemodynamically stable.

CONCLUSION:

It is possible to ventilate four adult-human-sized sheep on a single ventilator for at least 12h. This technique has the potential to improve disaster preparedness by expanding local ventilator surge capacity until emergency supplies can be delivered from central stockpiles. Further research should be conducted on ventilating individuals with different lung compliances and on potential microbial cross-contamination.

Comment in

PMID:
18164798
[PubMed - indexed for MEDLINE]
PubMed Commons home

PubMed Commons

0 comments
How to join PubMed Commons

    Supplemental Content

    Full text links

    Icon for Elsevier Science
    Loading ...
    Write to the Help Desk