Display Settings:

Format

Send to:

Choose Destination
    Clin Vaccine Immunol. 2008 Jan;15(1):42-8. Epub 2007 Nov 14.

    Simultaneous detection of eight analytes in human serum by two commercially available platforms for multiplex cytokine analysis.

    Source

    Department of Clinical Pathology and Experimental Medicine, Centocor R&D, 145 King of Prussia Road, Radnor, PA 19087, USA. gtoedter@cntus.jnj.com

    Abstract

    The accurate detection and quantitation of cytokines in serum are important in the study of disease mechanisms, pathogenesis, and treatment. Serum cytokines can reflect processes that are occurring at the cellular or tissue level and thus provide a means of indirectly monitoring these processes. Multiplex detection of cytokines allows the simultaneous measurement of multiple cytokines in a sample, increasing the efficiency of measuring the cytokines while reducing the serum sample volumes required for the testing. Two commercially available multiplex platforms were evaluated (Pierce SearchLight and Meso Scale Discovery), using multiplexes capable of simultaneously detecting eight cytokines. The cytokines analyzed in this study were gamma interferon, vascular endothelial growth factor, tumor necrosis factor alpha, interleukin-6 (IL-6), macrophage inflammatory protein 1beta, monocyte chemoattractant protein 1, IL-12p40, and IL-4. The range of quantitation of the platforms, the recovery of spiked cytokines, and the detection of the cytokines in serum samples from subjects with ulcerative colitis, Crohn's disease, rheumatoid arthritis, and psoriasis were examined. The findings showed that the detection of the cytokines was highly dependent upon the platform, with the consistency of the detection of cytokines across platforms being dependent upon the cytokine being analyzed. A careful examination of platform assay performance must be made prior to utilizing multiplex platforms in a study. While some cytokines will give similar patterns of results across platforms, others will be highly variable. The use of the same platform within a study or across studies where data will be compared is advised.

    PMID:
    18003817
    [PubMed - indexed for MEDLINE]
    PMCID:
    PMC2223861
    Free PMC Article

    Images from this publication.See all images (5) Free text

    FIG. 2.
    FIG. 4.
    FIG. 1.
    FIG. 3.
    FIG. 5.

      Supplemental Content

      Icon for HighWire Press Icon for PubMed Central

      Save items

      loading

      Recent activity

      Your browsing activity is empty.

      Activity recording is turned off.

      Turn recording back on

      See more...
      Write to the Help Desk